FireCADCalc

Ground Temperature at Depth through the Year (Kusuda)

Undisturbed ground temperature at a depth and day of the year from the annual mean and swing at the surface and the soil diffusivity, with damping and time lag.

Thermal power plant

Inputs

Examples: Illustrative 26 C mean, 8 K swing, 2 m, day 180Cold climate 8 C, 14 K, 1 m, day 30Deep 6 m, wet clay 1e-6

Accepted: -43.15 to 46.85 °C
Accepted: 0 to 30 K
Accepted: 1E-8 to 5E-6 m²/s
Accepted: 0 to 50 m
Accepted: 1 to 366
Accepted: 1 to 366

Results

Periodic conduction into a semi-infinite solid: T = T_m − A_s e^(−z/d) cos[2π(t − t₀)/365 − z/d], d = √(αP/π) with P one year. Snow, vegetation, groundwater flow and moisture changes are not modelled.

Ground temperature-1.0579°C
Annual amplitude at the depth9.3146K
Time lag behind the surface (days)23.671
Damping depth √(αP/π)2.4542m
Minimum temperature at the depth-1.3146°C
Maximum temperature at the depth17.315°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 26 C mean, 8 K swing, 2 m, day 180. The inputs, in the units selected above:

InputValue
Mean annual surface temperature26.000 °C
Annual surface temperature amplitude8.0000 K
Soil thermal diffusivity5.0000e-07 m²/s
Depth2.0000 m
Day of the year180.00 -
Day of minimum surface temperature15.000 -

Applying the formula below gives:

ResultValue
Ground temperature27.206 °C
Annual amplitude at the depth3.2763 K
Time lag behind the surface (days)51.860
Damping depth √(αP/π)2.2403 m
Minimum temperature at the depth22.724 °C
Maximum temperature at the depth29.276 °C

Open this example in the calculator and change any input.

Formula

\(T(z,t) = T_m - A_se^{-z/d}\cos\left[\frac{2\pi(t - t_0)}{365} - \frac{z}{d}\right], \quad d = \sqrt{\frac{\alpha P}{\pi}}\)

Variables

Symbol Meaning SI unit
\(T_m\) Mean annual surface temperature K
\(A_s\) Annual surface temperature amplitude K
\(\alpha\) Soil thermal diffusivity m²/s
\(z\) Depth m
\(t\) Day of the year -
\(t_0\) Day of minimum surface temperature -
\(T(z, t)\) Ground temperature K
\(A_z\) Annual amplitude at the depth K
\(\Delta t\) Time lag behind the surface (days) -
\(d\) Damping depth √(αP/π) m
\(T_{min}\) Minimum temperature at the depth K
\(T_{max}\) Maximum temperature at the depth K

Method and standards

Periodic heat conduction in the ground.

Where it is used

  • Ground-source heat pumps and earth-air tunnels.
  • Buried pipe frost depth and cable rating.

Common mistakes

  • Using air temperature swing for a snow-covered surface.
  • Mixing diffusivity in m²/day with seconds.

Assumptions and limits

  • Homogeneous soil; sinusoidal annual surface temperature.

References

  • Kusuda–Achenbach periodic ground temperature

Questions and answers

How deep must one go for a steady temperature?

The swing falls to about 5 % at three damping depths, typically 6–10 m; below that the ground stays near the annual mean.

Why is the ground warmest in autumn at 2–3 m?

The heat wave travels slowly downwards; at a damping depth it lags the surface by about two months.

What do the defaults represent?

An illustrative site with a 26 °C mean, an 8 K swing, soil diffusivity 5 × 10⁻⁷ m²/s, at 2 m depth on day 180 (coldest surface day 15).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Kusuda and Achenbach, Earth temperature and thermal diffusivity at selected stations in the United States, ASHRAE Transactions 71 (1965)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.