Worked example
Example: Illustrative 26 C mean, 8 K swing, 2 m, day 180. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean annual surface temperature | 26.000 °C |
| Annual surface temperature amplitude | 8.0000 K |
| Soil thermal diffusivity | 5.0000e-07 m²/s |
| Depth | 2.0000 m |
| Day of the year | 180.00 - |
| Day of minimum surface temperature | 15.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Ground temperature | 27.206 °C |
| Annual amplitude at the depth | 3.2763 K |
| Time lag behind the surface (days) | 51.860 |
| Damping depth √(αP/π) | 2.2403 m |
| Minimum temperature at the depth | 22.724 °C |
| Maximum temperature at the depth | 29.276 °C |
Open this example in the calculator and change any input.
Formula
\(T(z,t) = T_m - A_se^{-z/d}\cos\left[\frac{2\pi(t - t_0)}{365} - \frac{z}{d}\right], \quad d = \sqrt{\frac{\alpha P}{\pi}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_m\) | Mean annual surface temperature | K |
| \(A_s\) | Annual surface temperature amplitude | K |
| \(\alpha\) | Soil thermal diffusivity | m²/s |
| \(z\) | Depth | m |
| \(t\) | Day of the year | - |
| \(t_0\) | Day of minimum surface temperature | - |
| \(T(z, t)\) | Ground temperature | K |
| \(A_z\) | Annual amplitude at the depth | K |
| \(\Delta t\) | Time lag behind the surface (days) | - |
| \(d\) | Damping depth √(αP/π) | m |
| \(T_{min}\) | Minimum temperature at the depth | K |
| \(T_{max}\) | Maximum temperature at the depth | K |
Method and standards
Periodic heat conduction in the ground.
Where it is used
- Ground-source heat pumps and earth-air tunnels.
- Buried pipe frost depth and cable rating.
Common mistakes
- Using air temperature swing for a snow-covered surface.
- Mixing diffusivity in m²/day with seconds.
Assumptions and limits
- Homogeneous soil; sinusoidal annual surface temperature.
References
- Kusuda–Achenbach periodic ground temperature
Questions and answers
How deep must one go for a steady temperature?
The swing falls to about 5 % at three damping depths, typically 6–10 m; below that the ground stays near the annual mean.
Why is the ground warmest in autumn at 2–3 m?
The heat wave travels slowly downwards; at a damping depth it lags the surface by about two months.
What do the defaults represent?
An illustrative site with a 26 °C mean, an 8 K swing, soil diffusivity 5 × 10⁻⁷ m²/s, at 2 m depth on day 180 (coldest surface day 15).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Kusuda and Achenbach, Earth temperature and thermal diffusivity at selected stations in the United States, ASHRAE Transactions 71 (1965)