FireCADCalc

Geothermal Reservoir Heat in Place and Power Capacity

Heat stored in a geothermal reservoir by the volumetric method, and the electrical capacity it supports from recovery factor, conversion efficiency and plant life.

Thermal power plant

Inputs

Examples: Illustrative 10 km2, 1 km, 250 CSmall 3 km2, 500 m, 180 C, binary 9 %Large 50 km2, 2 km, 300 C

Accepted: 0.01 to 1,000 km²
Accepted: 10 to 5,000 m
Accepted: 26.85 to 426.85 °C
Accepted: 6.85 to 226.85 °C
Accepted: 0 to 50 %
Accepted: 1,000 to 4,000 kJ/Nm³
Accepted: 1,000 to 5,000 kJ/Nm³
Accepted: 0 to 100 %
Accepted: 0 to 30 %
Accepted: 3.169E-8 to 316.88 a
Accepted: 10 to 100 %

Results

Volumetric (heat-in-place) method: Q = Ah[(1 − φ)ρ_rc_r + φρ_wc_w](T_r − T_f); capacity = R_f η Q/(L·CF). Recovery factor (often 0.05–0.25) and efficiency carry most of the uncertainty; use Monte Carlo ranges for resource reporting.

Heat in place above the rejection temperature1.3828e+07GWh
Recoverable heat1,382,778GWh
Electrical energy over the life193,589GWh
Electrical capacity800.15MW
Capacity per km² (MW)16.003

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 10 km2, 1 km, 250 C. The inputs, in the units selected above:

InputValue
Reservoir area10.000 km²
Reservoir thickness1,000.0 m
Reservoir temperature250.00 °C
Rejection (abandonment) temperature80.000 °C
Porosity10.000 %
Rock volumetric heat capacity2,500.0 kJ/Nm³
Fluid volumetric heat capacity3,500.0 kJ/Nm³
Recovery factor15.000 %
Conversion efficiency to electricity12.000 %
Plant life30.000 a
Capacity factor90.000 %

Applying the formula below gives:

ResultValue
Heat in place above the rejection temperature1,227,778 GWh
Recoverable heat184,167 GWh
Electrical energy over the life22,100 GWh
Electrical capacity93.374 MW
Capacity per km² (MW)9.3374

Open this example in the calculator and change any input.

Formula

\(Q = Ah\left[(1 - \phi)\rho_rc_r + \phi\rho_wc_w\right](T_r - T_f), \quad P = \frac{R_f\eta Q}{L\cdot CF}\)

Variables

Symbol Meaning SI unit
\(A\) Reservoir area m²
\(h\) Reservoir thickness m
\(T_r\) Reservoir temperature K
\(T_f\) Rejection (abandonment) temperature K
\(\phi\) Porosity -
\(\rho_rc_r\) Rock volumetric heat capacity J/m³
\(\rho_wc_w\) Fluid volumetric heat capacity J/m³
\(R_f\) Recovery factor -
\(\eta\) Conversion efficiency to electricity -
\(L\) Plant life s
\(CF\) Capacity factor -
\(Q\) Heat in place above the rejection temperature J
\(Q_r\) Recoverable heat J
\(E\) Electrical energy over the life J
\(P\) Electrical capacity W
\(P/A\) Capacity per km² (MW) -

Method and standards

Volumetric resource estimate.

Where it is used

  • Early-stage resource assessment.
  • Checking development plans against reservoir size.

Common mistakes

  • Using the full heat in place without a recovery factor.
  • Choosing a rejection temperature below what the plant can use.

Assumptions and limits

  • Uniform reservoir properties; single deterministic estimate.

References

  • Volumetric heat-in-place method

Questions and answers

How many MW per km² do fields support?

Typically 5–20 MWe per km² for good high-temperature reservoirs, depending mostly on thickness, temperature and recovery factor.

Why is most of the heat in the rock?

Rock occupies 90 % or more of the volume and has a similar volumetric heat capacity, so it stores most of the heat; the fluid carries it out.

What do the defaults represent?

An illustrative 10 km², 1 km thick reservoir at 250 °C, abandoned at 80 °C, 10 % porosity, 15 % recovery, 12 % efficiency over 30 years at 90 % capacity factor.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Muffler and Cataldi, Methods for regional assessment of geothermal resources, Geothermics 7 (1978) 53–89, DiPippo, Geothermal Power Plants: Principles, Applications, Case Studies and Environmental Impact, 4th ed. (Butterworth-Heinemann, 2016), ch. 2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.