Worked example
Example: Illustrative 10 km2, 1 km, 250 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reservoir area | 10.000 km² |
| Reservoir thickness | 1,000.0 m |
| Reservoir temperature | 250.00 °C |
| Rejection (abandonment) temperature | 80.000 °C |
| Porosity | 10.000 % |
| Rock volumetric heat capacity | 2,500.0 kJ/Nm³ |
| Fluid volumetric heat capacity | 3,500.0 kJ/Nm³ |
| Recovery factor | 15.000 % |
| Conversion efficiency to electricity | 12.000 % |
| Plant life | 30.000 a |
| Capacity factor | 90.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat in place above the rejection temperature | 1,227,778 GWh |
| Recoverable heat | 184,167 GWh |
| Electrical energy over the life | 22,100 GWh |
| Electrical capacity | 93.374 MW |
| Capacity per km² (MW) | 9.3374 |
Open this example in the calculator and change any input.
Formula
\(Q = Ah\left[(1 - \phi)\rho_rc_r + \phi\rho_wc_w\right](T_r - T_f), \quad P = \frac{R_f\eta Q}{L\cdot CF}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Reservoir area | m² |
| \(h\) | Reservoir thickness | m |
| \(T_r\) | Reservoir temperature | K |
| \(T_f\) | Rejection (abandonment) temperature | K |
| \(\phi\) | Porosity | - |
| \(\rho_rc_r\) | Rock volumetric heat capacity | J/m³ |
| \(\rho_wc_w\) | Fluid volumetric heat capacity | J/m³ |
| \(R_f\) | Recovery factor | - |
| \(\eta\) | Conversion efficiency to electricity | - |
| \(L\) | Plant life | s |
| \(CF\) | Capacity factor | - |
| \(Q\) | Heat in place above the rejection temperature | J |
| \(Q_r\) | Recoverable heat | J |
| \(E\) | Electrical energy over the life | J |
| \(P\) | Electrical capacity | W |
| \(P/A\) | Capacity per km² (MW) | - |
Method and standards
Volumetric resource estimate.
Where it is used
- Early-stage resource assessment.
- Checking development plans against reservoir size.
Common mistakes
- Using the full heat in place without a recovery factor.
- Choosing a rejection temperature below what the plant can use.
Assumptions and limits
- Uniform reservoir properties; single deterministic estimate.
References
- Volumetric heat-in-place method
Questions and answers
How many MW per km² do fields support?
Typically 5–20 MWe per km² for good high-temperature reservoirs, depending mostly on thickness, temperature and recovery factor.
Why is most of the heat in the rock?
Rock occupies 90 % or more of the volume and has a similar volumetric heat capacity, so it stores most of the heat; the fluid carries it out.
What do the defaults represent?
An illustrative 10 km², 1 km thick reservoir at 250 °C, abandoned at 80 °C, 10 % porosity, 15 % recovery, 12 % efficiency over 30 years at 90 % capacity factor.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Muffler and Cataldi, Methods for regional assessment of geothermal resources, Geothermics 7 (1978) 53–89, DiPippo, Geothermal Power Plants: Principles, Applications, Case Studies and Environmental Impact, 4th ed. (Butterworth-Heinemann, 2016), ch. 2