Worked example
Example: Illustrative 40 kg/s, 85 to 45 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Geothermal water flow | 144,000 kg/h |
| Supply temperature | 85.000 °C |
| Return (reinjection) temperature | 45.000 °C |
| Annual load factor | 45.000 % |
| Efficiency of the boiler replaced | 88.000 % |
| Fuel emission factor (kg CO₂ per GJ; gas 56) | 56.100 - |
| Well and circulation pump power | 150.00 kW |
| Grid emission factor (kg CO₂ per kWh) | 0.40000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat output | 6.6985 MW |
| Heat delivered per year | 26.406 GWh |
| Fuel displaced per year | 108,023 GJ |
| CO₂ avoided per year, net of pumping | 5.8236 t |
| Heat delivered per unit of pump power | 44.657 |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m(h_{in} - h_{out}), \quad E_f = \frac{\dot Q\,LF\,t}{\eta_b}, \quad m_{CO_2} = E_f\,EF - P_p\,LF\,t\,EF_e\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Geothermal water flow | kg/s |
| \(T_{in}\) | Supply temperature | K |
| \(T_{out}\) | Return (reinjection) temperature | K |
| \(LF\) | Annual load factor | - |
| \(\eta_b\) | Efficiency of the boiler replaced | - |
| \(EF\) | Fuel emission factor (kg CO₂ per GJ; gas 56) | - |
| \(P_p\) | Well and circulation pump power | W |
| \(EF_e\) | Grid emission factor (kg CO₂ per kWh) | - |
| \(\dot Q\) | Heat output | W |
| \(E\) | Heat delivered per year | J |
| \(E_f\) | Fuel displaced per year | J |
| \(m_{CO_2}\) | CO₂ avoided per year, net of pumping | kg |
| \(Q/P_p\) | Heat delivered per unit of pump power | - |
Method and standards
Direct-use energy balance.
Where it is used
- District heating and greenhouse heating with geothermal water.
- Comparing heating options.
Common mistakes
- Using the full-year output without a load factor.
- Ignoring pump electricity.
Assumptions and limits
- Steady flow; constant return temperature.
References
- Direct-use heat and displaced fuel balance
Questions and answers
How much heat does a geothermal well give?
About 6.7 MW from 40 kg/s cooled from 85 °C to 45 °C; well flows of 20–100 kg/s are common in sedimentary aquifers.
Why include pump power?
Deep well pumps and circulation use electricity; the saving is the fuel avoided less the emissions from that electricity.
What do the defaults represent?
An illustrative doublet: 40 kg/s at 85 °C returned at 45 °C, 45 % load factor, replacing an 88 % gas boiler, with 150 kW of pumps on a 0.4 kg/kWh grid.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
DiPippo, Geothermal Power Plants, 4th ed. (Butterworth-Heinemann, 2016), ch. 15, Kothari, Singal and Ranjan, Renewable Energy Sources and Emerging Technologies, 2nd ed. (PHI, 2011)