Worked example
Example: Illustrative 120 kg/s, 160 to 70 C, 12 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Brine flow | 432,000 kg/h |
| Brine inlet temperature | 160.00 °C |
| Brine reinjection temperature | 70.000 °C |
| Net cycle thermal efficiency | 12.000 % |
| Dead-state (ambient) temperature | 25.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat taken from the brine | 45.907 MW |
| Net power | 5.5088 MW |
| Exergy of the brine entering | 12.119 MW |
| Utilisation efficiency | 45.455 % |
| Ideal triangular-cycle efficiency | 18.460 % |
| Cycle efficiency relative to the triangular ideal | 65.004 % |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m(h_{in} - h_{out}), \quad \eta_u = \frac{\dot W}{\dot m\left[(h_{in} - h_0) - T_0(s_{in} - s_0)\right]}, \quad \eta_{TRI} = \frac{T_H - T_L}{T_H + T_L}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Brine flow | kg/s |
| \(T_{in}\) | Brine inlet temperature | K |
| \(T_{out}\) | Brine reinjection temperature | K |
| \(\eta_{th}\) | Net cycle thermal efficiency | - |
| \(T_0\) | Dead-state (ambient) temperature | K |
| \(\dot Q\) | Heat taken from the brine | W |
| \(\dot W\) | Net power | W |
| \(\dot E\) | Exergy of the brine entering | W |
| \(\eta_u\) | Utilisation efficiency | - |
| \(\eta_{TRI}\) | Ideal triangular-cycle efficiency | - |
| \(\eta_{th}/\eta_{TRI}\) | Cycle efficiency relative to the triangular ideal | - |
Method and standards
Binary plant energy and exergy.
Where it is used
- Low-temperature geothermal and waste-heat ORC screening.
- Comparing flash and binary options.
Common mistakes
- Comparing with the Carnot efficiency instead of the triangular cycle.
- Ignoring the reinjection temperature limit.
Assumptions and limits
- Brine as pure water; cycle efficiency entered, not calculated.
References
- Binary-cycle energy and exergy balance; ideal triangular cycle
Questions and answers
Why are binary plant efficiencies so low?
A 160 °C brine is only about 135 K above ambient; even an ideal cycle that cools it to ambient converts only about 18 %, and real ones about 10–14 %.
Why is reinjection temperature limited?
Cooling brine too far precipitates silica and other minerals in exchangers and wells, so 60–80 °C is common.
What do the defaults represent?
An illustrative 120 kg/s of brine at 160 °C reinjected at 70 °C, with a 12 % net cycle efficiency and a 25 °C ambient.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
DiPippo, Geothermal Power Plants: Principles, Applications, Case Studies and Environmental Impact, 4th ed. (Butterworth-Heinemann, 2016), ch. 8