FireCADCalc

Binary Geothermal Plant Heat, Power and Utilisation

Heat taken from geothermal brine, net power at a cycle efficiency, the ideal triangular-cycle efficiency, and the exergy utilisation of a binary (ORC) plant.

Thermal power plant

Inputs

Examples: Illustrative 120 kg/s, 160 to 70 C, 12 %Low-temperature 110 to 60 C, 8 %Hot brine 190 to 85 C, 14 %

Accepted: 360 to 18,000,000 kg/h
Accepted: 56.85 to 246.85 °C
Accepted: 16.85 to 226.85 °C
Accepted: 1 to 30 %
Accepted: -13.15 to 46.85 °C

Results

Brine as saturated liquid (pressurised to stay liquid); ideal triangular cycle η_TRI = (T_H − T_L)/(T_H + T_L) for a source cooled to the sink temperature. Real binary plants reach about half to two-thirds of η_TRI. Water and steam properties from IAPWS-IF97.

Heat taken from the brine36.130MW
Net power5.0581MW
Exergy of the brine entering11.650MW
Utilisation efficiency43.417%
Ideal triangular-cycle efficiency21.673%
Cycle efficiency relative to the triangular ideal64.595%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 120 kg/s, 160 to 70 C, 12 %. The inputs, in the units selected above:

InputValue
Brine flow432,000 kg/h
Brine inlet temperature160.00 °C
Brine reinjection temperature70.000 °C
Net cycle thermal efficiency12.000 %
Dead-state (ambient) temperature25.000 °C

Applying the formula below gives:

ResultValue
Heat taken from the brine45.907 MW
Net power5.5088 MW
Exergy of the brine entering12.119 MW
Utilisation efficiency45.455 %
Ideal triangular-cycle efficiency18.460 %
Cycle efficiency relative to the triangular ideal65.004 %

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m(h_{in} - h_{out}), \quad \eta_u = \frac{\dot W}{\dot m\left[(h_{in} - h_0) - T_0(s_{in} - s_0)\right]}, \quad \eta_{TRI} = \frac{T_H - T_L}{T_H + T_L}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Brine flow kg/s
\(T_{in}\) Brine inlet temperature K
\(T_{out}\) Brine reinjection temperature K
\(\eta_{th}\) Net cycle thermal efficiency -
\(T_0\) Dead-state (ambient) temperature K
\(\dot Q\) Heat taken from the brine W
\(\dot W\) Net power W
\(\dot E\) Exergy of the brine entering W
\(\eta_u\) Utilisation efficiency -
\(\eta_{TRI}\) Ideal triangular-cycle efficiency -
\(\eta_{th}/\eta_{TRI}\) Cycle efficiency relative to the triangular ideal -

Method and standards

Binary plant energy and exergy.

Where it is used

  • Low-temperature geothermal and waste-heat ORC screening.
  • Comparing flash and binary options.

Common mistakes

  • Comparing with the Carnot efficiency instead of the triangular cycle.
  • Ignoring the reinjection temperature limit.

Assumptions and limits

  • Brine as pure water; cycle efficiency entered, not calculated.

References

  • Binary-cycle energy and exergy balance; ideal triangular cycle

Questions and answers

Why are binary plant efficiencies so low?

A 160 °C brine is only about 135 K above ambient; even an ideal cycle that cools it to ambient converts only about 18 %, and real ones about 10–14 %.

Why is reinjection temperature limited?

Cooling brine too far precipitates silica and other minerals in exchangers and wells, so 60–80 °C is common.

What do the defaults represent?

An illustrative 120 kg/s of brine at 160 °C reinjected at 70 °C, with a 12 % net cycle efficiency and a 25 °C ambient.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

DiPippo, Geothermal Power Plants: Principles, Applications, Case Studies and Environmental Impact, 4th ed. (Butterworth-Heinemann, 2016), ch. 8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.