Solar PV Energy Generation (kWh per Year)

Daily and annual energy from a solar PV plant from its kWp rating, the plane-of-array irradiation (peak sun hours) and the performance ratio, with CUF and specific yield.

Inputs

Examples: 1 MWp, 5.2 kWh/m²/day, PR 0.78, 365 daysRooftop 100 kWp, 4.5, 0.75, 3655 MWp, 5.8, 0.8, 30 days

Yearly mean daily irradiation on the tilted plane, from a solar resource database for the site.
Covers temperature, soiling, mismatch, cable, inverter and transformer losses; typically 0.75–0.82 for a well-run plant.

Results

The energy is AC at the meter only if the performance ratio includes inverter and transformer losses; module degradation (about 0.5 % a year) is not included.

Energy per day337.50kWh
Energy in the period123.19MWh
Specific yield (kWh per kWp)1,231.9
Capacity utilisation factor (on DC kWp)14.062%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 MWp, 5.2 kWh/m²/day, PR 0.78, 365 days. The inputs, in the units selected above:

InputValue
Plant rating (DC, at STC)1,000.0 kW
Irradiation on the modules (kWh/m² per day = peak sun hours)5.2000 -
Performance ratio78.000 %
Days in the period365.00 -

Applying the formula below gives:

ResultValue
Energy per day4,056.0 kWh
Energy in the period1,480.4 MWh
Specific yield (kWh per kWp)1,480.4
Capacity utilisation factor (on DC kWp)16.900 %

Open this example in the calculator and change any input.

Formula

\(E_d = P_{pk}\,H\,PR \qquad E = E_d\,d \qquad Y_f = H\,PR\,d \qquad CUF = \frac{H\,PR}{24}\)

Variables

Symbol Meaning SI unit
\(P_{pk}\) DC rating at STC W
\(H\) daily irradiation on the modules (peak sun hours) kWh/m² per day
\(PR\) performance ratio –
\(d\) days –
\(E_d\) energy per day J
\(E\) energy in the period J
\(Y_f\) specific yield kWh/kWp
\(CUF\) capacity utilisation factor, on the DC kWp rating –

Method and standards

Reference yield (irradiation over 1 kW/m²) times performance ratio, as defined in IEC 61724-1.

Where it is used

  • Captive solar plant feasibility.
  • Monitoring plant performance.
  • Carbon accounting.

Common mistakes

  • Using horizontal irradiation for tilted modules.
  • Taking PR above 0.85 for warm climates.
  • Forgetting degradation over the years.

Assumptions and limits

  • Yearly mean conditions; degradation and curtailment not included.
  • CUF is on the DC (kWp) rating; Indian plant reports often quote it on the AC (inverter) capacity, which is higher by the DC/AC ratio.

References

  • IEC 61724-1 (performance ratio definition)

Questions and answers

How much does a 1 MWp plant make in a year?

With 5.2 kWh/m²/day on the modules and PR 0.78: 14.6 MWh a day, 5330 MWh a year, 1480 kWh/kWp and a CUF of 16.9 %.

What is the performance ratio?

Actual energy over the energy the array would give at STC efficiency; it covers temperature, soiling, wiring and inverter losses.

Is CUF on DC or AC rating?

Here on DC kWp; on AC rating it is higher by the DC/AC ratio.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.