Solar PV Array Size for a Daily Energy Need

kWp, number of modules and roof or ground area needed for a daily energy requirement, from peak sun hours, performance ratio and module rating.

Inputs

Examples: 400 kWh/day, 5 h, PR 0.78, 550 Wp modules 2.58 m², GCR 0.550 kWh/day, 4.5 h, 0.75, 450 Wp 2.1 m², roof 0.92000 kWh/day, 5.5 h, 0.8, 600 Wp 2.7 m², 0.45

Module area ÷ land or roof area, to leave room for row spacing and access; about 0.4–0.6 for tilted rows, near 0.9 for flush roof mounting.

Results

Sized on the yearly mean irradiation: an off-grid system must be sized on the worst month and needs battery storage.

E_d is energy at the meter (AC) only if the performance ratio includes inverter and transformer losses; otherwise it is DC energy at the array.

Array rating needed (DC)14.815kW
Number of modules (whole)33.000
Array rating with whole modules14.850kW
Module area in total69.300m²
Roof or land area77.000m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 400 kWh/day, 5 h, PR 0.78, 550 Wp modules 2.58 m², GCR 0.5. The inputs, in the units selected above:

InputValue
Energy needed per day400.00 kWh
Irradiation on the modules (kWh/m² per day = peak sun hours)5.0000 -
Performance ratio78.000 %
Module rating (Wp)550.00 W
Module area2.5800 m²
Ground (roof) coverage ratio50.000 %

Applying the formula below gives:

ResultValue
Array rating needed (DC)102.56 kW
Number of modules (whole)187.00
Array rating with whole modules102.85 kW
Module area in total482.46 m²
Roof or land area964.92 m²

Open this example in the calculator and change any input.

Formula

\(P_{pk} = \frac{E_d}{H\,PR} \qquad N = \left\lceil \frac{P_{pk}}{P_m} \right\rceil \qquad P_{act} = N P_m \qquad A_l = \frac{N A_m}{GCR}\)

Variables

Symbol Meaning SI unit
\(E_d\) energy needed per day (AC at the meter if PR includes inverter and transformer losses) J
\(H\) peak sun hours h/day
\(PR\) performance ratio –
\(P_m\) module rating W
\(A_m\) module area m²
\(GCR\) ground coverage ratio –
\(P_{pk}\) array rating needed W
\(N\) number of modules –
\(P_{act}\) rating with whole modules W
\(A_m N\) module area in total m²
\(A_l\) roof or land area m²

Method and standards

Inverse of the reference-yield relation of IEC 61724-1, rounded up to whole modules.

Where it is used

  • Rooftop solar on plant buildings.
  • Solar for pumping and lighting.
  • Land estimates for ground-mounted plants.

Common mistakes

  • Using the module's area efficiency instead of PR.
  • Ignoring shading from stacks and structures.
  • Sizing on yearly mean for off-grid loads.

Assumptions and limits

  • Yearly mean irradiation; string and inverter design separate.
  • E_d is AC energy only when the performance ratio includes inverter and transformer losses.
  • Module rating and area are independent inputs; the page warns when they imply an efficiency outside 5–30 % at 1000 W/m².

References

  • IEC 61724-1 (performance ratio definition)

Questions and answers

What array covers 400 kWh a day?

At 5 peak sun hours and PR 0.78: 102.6 kWp, or 187 modules of 550 Wp (102.9 kWp) on about 965 m² at a coverage ratio of 0.5.

Why the coverage ratio?

Tilted rows need space between them to avoid shading; flush roof mounting can use most of the area.

Is this enough for off-grid?

No. Off-grid systems are sized on the worst month and need batteries.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.