Worked example
Example: 2 m table at 20°, latitude 20° N, December solstice, 9 am. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Sloping length of the panel table | 2.0000 m |
| Tilt of the panels | 20.000 ° |
| Latitude (north positive) | 20.000 ° |
| Solar declination on the design day | -23.440 ° |
| Hour angle (15° per hour from solar noon) | 45.000 ° |
Applying the formula below gives:
| Result | Value |
|---|---|
| Height of the top edge above the bottom edge | 0.68404 m |
| Solar altitude | 28.267 ° |
| Solar azimuth from the equator direction | 47.442 ° |
| Clear gap between rows | 0.86041 m |
| Row pitch (gap plus the plan length of the table) | 2.7398 m |
Open this example in the calculator and change any input.
Formula
\(\sin\alpha = \sin\varphi \sin\delta + \cos\varphi \cos\delta \cos\omega\)
\(\tan\gamma = \frac{\sin\omega \cos\delta}{\cos\omega \cos\delta \sin\varphi - \sin\delta \cos\varphi}\)
\(d = \frac{L \sin\beta}{\tan\alpha} \cos\gamma, \quad p = d + L \cos\beta\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Sloping length of the panel table | m |
| \(\beta\) | Tilt of the panels | rad |
| \(\varphi\) | Latitude (north positive) | rad |
| \(\delta\) | Solar declination on the design day | rad |
| \(\omega\) | Hour angle (15° per hour from solar noon) | rad |
| \(h\) | Height of the top edge above the bottom edge | m |
| \(\alpha\) | Solar altitude | rad |
| \(\gamma\) | Solar azimuth from the equator direction | rad |
| \(d\) | Clear gap between rows | m |
| \(p\) | Row pitch (gap plus the plan length of the table) | m |
Method and standards
Sun position from latitude, declination and hour angle; shadow of the top edge projected on the row direction.
Where it is used
- Ground-mount and flat-roof layouts.
Common mistakes
- Using noon altitude only.
- Clock time instead of solar time.
Assumptions and limits
- Level ground, rows facing the equator.
- Shading is checked at one instant, the hour angle you enter. The sun path is symmetric about solar noon, so 9 am and 3 pm give the same spacing; enter the hour angle as a positive number.
- The calculation stops when the sun is less than about 1° above the horizon (sin α ≤ 0.02), a practical cut-off: rows cannot be spaced for a sun that low.
References
- Solar geometry (Duffie and Beckman, Solar Engineering of Thermal Processes, ch. 1)
Questions and answers
What decides the spacing?
The lowest sun you want to stay unshaded for: usually 9 am to 3 pm on the shortest day.
Why multiply by the cosine of the azimuth?
Only the part of the shadow that falls towards the next row matters.
Does a slope change it?
Yes; a slope towards the equator shortens the spacing. This calculator is for level ground.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.