FireCADCalc

Solar Panel Row Spacing to Avoid Shading

Gap and pitch between rows of tilted solar panels so that one row does not shade the next, from the tilt, latitude, date (declination) and time of day.

Inputs

Examples: 2 m table at 20°, latitude 20° N, December solstice, 9 am4 m table at 25°, latitude 28° N, December solstice, 10 am2.3 m at 30°, latitude 35° S, June solstice, 9 am

−23.44° at the December solstice, +23.44° in June, 0° at the equinoxes.

Results

Rows facing the equator on level ground. The usual design case is the winter solstice at 9 am or 3 pm solar time (hour angle 45°).

Height of the top edge above the bottom edge0.68404m
Solar altitude28.267°
Solar azimuth from the equator direction47.442°
Clear gap between rows0.86041m
Row pitch (gap plus the plan length of the table)2.7398m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 m table at 20°, latitude 20° N, December solstice, 9 am. The inputs, in the units selected above:

InputValue
Sloping length of the panel table2.0000 m
Tilt of the panels20.000 °
Latitude (north positive)20.000 °
Solar declination on the design day-23.440 °
Hour angle (15° per hour from solar noon)45.000 °

Applying the formula below gives:

ResultValue
Height of the top edge above the bottom edge0.68404 m
Solar altitude28.267 °
Solar azimuth from the equator direction47.442 °
Clear gap between rows0.86041 m
Row pitch (gap plus the plan length of the table)2.7398 m

Open this example in the calculator and change any input.

Formula

\(\sin\alpha = \sin\varphi \sin\delta + \cos\varphi \cos\delta \cos\omega\)

\(\tan\gamma = \frac{\sin\omega \cos\delta}{\cos\omega \cos\delta \sin\varphi - \sin\delta \cos\varphi}\)

\(d = \frac{L \sin\beta}{\tan\alpha} \cos\gamma, \quad p = d + L \cos\beta\)

Variables

Symbol Meaning SI unit
\(L\) Sloping length of the panel table m
\(\beta\) Tilt of the panels rad
\(\varphi\) Latitude (north positive) rad
\(\delta\) Solar declination on the design day rad
\(\omega\) Hour angle (15° per hour from solar noon) rad
\(h\) Height of the top edge above the bottom edge m
\(\alpha\) Solar altitude rad
\(\gamma\) Solar azimuth from the equator direction rad
\(d\) Clear gap between rows m
\(p\) Row pitch (gap plus the plan length of the table) m

Method and standards

Sun position from latitude, declination and hour angle; shadow of the top edge projected on the row direction.

Where it is used

  • Ground-mount and flat-roof layouts.

Common mistakes

  • Using noon altitude only.
  • Clock time instead of solar time.

Assumptions and limits

  • Level ground, rows facing the equator.
  • Shading is checked at one instant, the hour angle you enter. The sun path is symmetric about solar noon, so 9 am and 3 pm give the same spacing; enter the hour angle as a positive number.
  • The calculation stops when the sun is less than about 1° above the horizon (sin α ≤ 0.02), a practical cut-off: rows cannot be spaced for a sun that low.

References

  • Solar geometry (Duffie and Beckman, Solar Engineering of Thermal Processes, ch. 1)

Questions and answers

What decides the spacing?

The lowest sun you want to stay unshaded for: usually 9 am to 3 pm on the shortest day.

Why multiply by the cosine of the azimuth?

Only the part of the shadow that falls towards the next row matters.

Does a slope change it?

Yes; a slope towards the equator shortens the spacing. This calculator is for level ground.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.