Trigonometric Levelling: Height of an Inaccessible Point

Horizontal distance and height of an inaccessible point (chimney top, tower) from vertical angles at two instrument stations in line with it and a measured base.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: Chimney: 40° and 25°, stations 30 m apartTower: 30° and 20°, 50 m base

Results

Stations and object in one vertical plane, instrument axis at the same level at both stations. For sights beyond about 300 m add the curvature and refraction correction.

Horizontal distance from the near station85.287m
Height above the instrument axis49.240m
Reduced level of the point300.64m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Chimney: 40° and 25°, stations 30 m apart. The inputs, in the units selected above:

InputValue
Distance between the two stations30.000 m
Vertical angle from the near station40.000 °
Vertical angle from the far station25.000 °
Reduced level of the instrument axis (both stations)100.00 m

Applying the formula below gives:

ResultValue
Horizontal distance from the near station37.526 m
Height above the instrument axis31.488 m
Reduced level of the point131.49 m

Open this example in the calculator and change any input.

Formula

\(D = \frac{b\tan\alpha_2}{\tan\alpha_1 - \tan\alpha_2}, \quad h = D\tan\alpha_1\)

Variables

Symbol Meaning SI unit
\(b\) Distance between the two stations m
\(\alpha_1\) Vertical angle from the near station rad
\(\alpha_2\) Vertical angle from the far station rad
\(RL_i\) Reduced level of the instrument axis (both stations) m
\(D\) Horizontal distance from the near station m
\(h\) Height above the instrument axis m
\(RL\) Reduced level of the point m

Method and standards

Trigonometry.

Where it is used

  • Chimney and tower heights.
  • Exam problems.

Common mistakes

  • Stations not in line with the object.
  • Mixing up near and far angles.

Assumptions and limits

  • Same instrument level; short sights.

References

  • Trigonometric levelling
  • base inaccessible
  • stations in line (Punmia, Surveying, vol. 1–2 (Laxmi), vol. 2)

Questions and answers

Why two stations?

When the base of the object cannot be reached, its distance is unknown; two angles over a measured base give both distance and height.

What if the instrument heights differ?

Then the formula needs the height difference term; set both stations at the same axis level where possible.

What do the defaults represent?

Angles of 40° and 25° to a chimney top from stations 30 m apart.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.