Worked example
Example: Elevation 6 degrees. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Staff intercept (top − bottom hair) | 1.2500 m |
| Vertical angle (positive elevation) | 6.0000 ° |
| Multiplying constant | 100.00 - |
| Additive constant | 0 m |
| Reduced level of the instrument station | 150.00 m |
| Height of the instrument axis | 1.4500 m |
| Middle hair reading | 1.8750 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Horizontal distance K s cos²θ + C cos θ | 123.63 m |
| Vertical component K s sinθ cosθ + C sin θ | 12.994 m |
| Reduced level of the staff station | 162.57 m |
Open this example in the calculator and change any input.
Formula
\(D = K s\cos^2\theta + C\cos\theta, \quad V = K s\sin\theta\cos\theta + C\sin\theta, \quad RL_p = RL_s + h_i + V - h\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(s\) | Staff intercept (top − bottom hair) | m |
| \(\theta\) | Vertical angle (positive elevation) | rad |
| \(K\) | Multiplying constant | - |
| \(C\) | Additive constant | m |
| \(RL_s\) | Reduced level of the instrument station | m |
| \(h_i\) | Height of the instrument axis | m |
| \(h\) | Middle hair reading | m |
| \(D\) | Horizontal distance K s cos²θ + C cos θ | m |
| \(V\) | Vertical component K s sinθ cosθ + C sin θ | m |
| \(RL_p\) | Reduced level of the staff station | m |
Method and standards
Stadia geometry.
Where it is used
- Contour and detail surveys.
- Surveying examinations.
Common mistakes
- Forgetting cos² on inclined sights.
- Sign of depression angles.
Assumptions and limits
- Vertical staff.
References
- Stadia tacheometry with a vertical staff (surveying texts)
Questions and answers
Intercept 1.25 m at +6°, K 100?
Horizontal distance 123.63 m, rise 12.99 m.
Modern instruments?
Total stations measure distance directly; stadia stays in exams and quick work.
Additive constant?
Zero for internal-focusing telescopes.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.