FireCADCalc

Superelevation and Side Friction on a Horizontal Curve

Superelevation and side friction needed on a horizontal road curve for a design speed and radius (e + f = v²/gR), the minimum radius and the safe speed.

Inputs

Examples: 80 km/h on 300 mPlant road 30 km/h on 40 mGentle curve, no superelevation needed

From your road standard.
From your road standard for the speed.

Results

Road standards add rules on how superelevation and friction share the load; follow yours for design.

Total needed v²/(gR)0.024588
Superelevation needed if friction takes its full share0%
Minimum radius for e_max and f85.524m
Safe speed on this radius152.92km/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 80 km/h on 300 m. The inputs, in the units selected above:

InputValue
Design speed80.000 km/h
Curve radius300.00 m
Maximum superelevation allowed7.0000 %
Side friction factor allowed0.15000 -

Applying the formula below gives:

ResultValue
Total needed v²/(gR)0.16785
Superelevation needed if friction takes its full share1.7855 %
Minimum radius for e_max and f228.89 m
Safe speed on this radius91.587 km/h

Open this example in the calculator and change any input.

Formula

\(e + f = \frac{v^2}{g R}, \quad R_{min} = \frac{v^2}{g(e_{max} + f)}\)

Variables

Symbol Meaning SI unit
\(v\) Design speed m/s
\(R\) Curve radius m
\(e_{max}\) Maximum superelevation allowed -
\(f\) Side friction factor allowed -
\(e + f\) Total needed v²/(gR) -
\(e_n\) Superelevation needed if friction takes its full share -
\(R_{min}\) Minimum radius for e_max and f m
\(v_{safe}\) Safe speed on this radius m/s

Method and standards

Equilibrium on a banked curve.

Where it is used

  • Road and plant road design.
  • Speed limits on bends.

Common mistakes

  • km/h in the formula.
  • Ignoring standard limits.

Assumptions and limits

  • Point mass, small angles.
  • When e_n exceeds e_max (radius below R_min) the page warns: the curve cannot carry the design speed within the allowed superelevation and friction.

References

  • Point-mass equilibrium on a banked curve
  • e + f = v²/(gR) (AASHTO and IRC basic relation)

Questions and answers

80 km/h on a 300 m radius?

e + f = 0.168; minimum radius 229 m with e 7 % and f 0.15.

Why limit superelevation?

Slow vehicles would slide inwards on a steep bank.

Plant roads?

Low speeds need little superelevation but tight radii still need checks.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators