FireCADCalc

Blast Vibration: Scaled Distance, PPV and Charge per Delay

Square-root scaled distance, predicted peak particle velocity from site constants, and the largest charge per delay for a scaled distance or PPV limit.

Inputs

Examples: 500 lb per delay at 1,500 ft, USBM vertical average2,000 lb at 3,000 ft, radial average50 lb at 300 ft, transverse average

Accepted: 3.2808 to 328,080 ft
Accepted: 0.022046 to 220,460 lb
Accepted: 1 to 2,000
Accepted: -4 to -0.5
Accepted: 10 to 200
Accepted: 0.003937 to 39.37 in/s

Results

The site constants come from a regression of measured PPV against scaled distance at the site; the defaults are the USBM average for the vertical component (k 156, m −1.642). Damage limits depend on frequency as well as PPV.

Scaled distance (ft/lb½)42.426
Scaled distance (m/kg½)19.201
Predicted peak particle velocity0.36201in/s
Charge per delay allowed by the scaled-distance limit21.302lb
Charge per delay allowed by the PPV limit608.43lb

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 500 lb per delay at 1,500 ft, USBM vertical average. The inputs, in the units selected above:

InputValue
Distance from blast to the nearest structure1,500.0 ft
Largest charge per 8 ms delay500.00 lb
Site constant k (PPV in in/s at a scaled distance of 1 ft/lb½)156.00 -
Site constant m (slope, negative)-1.6420 -
Scaled-distance limit55.000 -
PPV limit1.0000 in/s

Applying the formula below gives:

ResultValue
Scaled distance (ft/lb½)67.082
Scaled distance (m/kg½)30.359
Predicted peak particle velocity0.15626 in/s
Charge per delay allowed by the scaled-distance limit743.80 lb
Charge per delay allowed by the PPV limit4,796.2 lb

Open this example in the calculator and change any input.

Formula

\(S = \frac{D}{\sqrt W}, \quad V = kS^{m}, \quad W_{max} = \left(\frac{D}{D_s}\right)^2\)

Variables

Symbol Meaning SI unit
\(D\) Distance from blast to the nearest structure m
\(W\) Largest charge per 8 ms delay kg
\(k\) Site constant k (PPV in in/s at a scaled distance of 1 ft/lb½) -
\(m\) Site constant m (slope, negative) -
\(D_s\) Scaled-distance limit -
\(V_{lim}\) PPV limit m/s
\(S\) Scaled distance (ft/lb½) -
\(S_{SI}\) Scaled distance (m/kg½) -
\(V\) Predicted peak particle velocity m/s
\(W_{D_s}\) Charge per delay allowed by the scaled-distance limit kg
\(W_V\) Charge per delay allowed by the PPV limit kg

Method and standards

Square-root scaled distance and the PPV attenuation law.

Where it is used

  • Blast permits near buildings.
  • Delay design to limit vibration.

Common mistakes

  • Using total charge instead of charge per delay.
  • Applying another site's constants without measurement.

Assumptions and limits

  • Empirical regression; wide scatter about the mean line.

Questions and answers

What scaled distance keeps a blast safe?

Regulators use fixed scaled distances such as 50, 55 or 65 ft/lb½, statistically shown to keep vibration below the usual limits.

Why does the charge per delay matter and not the total?

Delays separate the detonations so each wave arrives alone; the largest charge firing within about 8 ms sets the vibration.

What do the defaults represent?

500 lb per delay at 1,500 ft: scaled distance 67 ft/lb½ and a predicted 0.16 in/s with the USBM vertical average; a 55 ft/lb½ limit allows 744 lb per delay.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Dougherty and Schissler (eds.), SME Mining Reference Handbook, 2nd ed. (SME, 2020), ch. 11, eqs. 11.51-11.52 and Table 11.8 (Siskind et al., USBM RI 8507, 1980)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.