Worked example
Example: 500 lb per delay at 1,500 ft, USBM vertical average. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Distance from blast to the nearest structure | 1,500.0 ft |
| Largest charge per 8 ms delay | 500.00 lb |
| Site constant k (PPV in in/s at a scaled distance of 1 ft/lb½) | 156.00 - |
| Site constant m (slope, negative) | -1.6420 - |
| Scaled-distance limit | 55.000 - |
| PPV limit | 1.0000 in/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Scaled distance (ft/lb½) | 67.082 |
| Scaled distance (m/kg½) | 30.359 |
| Predicted peak particle velocity | 0.15626 in/s |
| Charge per delay allowed by the scaled-distance limit | 743.80 lb |
| Charge per delay allowed by the PPV limit | 4,796.2 lb |
Open this example in the calculator and change any input.
Formula
\(S = \frac{D}{\sqrt W}, \quad V = kS^{m}, \quad W_{max} = \left(\frac{D}{D_s}\right)^2\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Distance from blast to the nearest structure | m |
| \(W\) | Largest charge per 8 ms delay | kg |
| \(k\) | Site constant k (PPV in in/s at a scaled distance of 1 ft/lb½) | - |
| \(m\) | Site constant m (slope, negative) | - |
| \(D_s\) | Scaled-distance limit | - |
| \(V_{lim}\) | PPV limit | m/s |
| \(S\) | Scaled distance (ft/lb½) | - |
| \(S_{SI}\) | Scaled distance (m/kg½) | - |
| \(V\) | Predicted peak particle velocity | m/s |
| \(W_{D_s}\) | Charge per delay allowed by the scaled-distance limit | kg |
| \(W_V\) | Charge per delay allowed by the PPV limit | kg |
Method and standards
Square-root scaled distance and the PPV attenuation law.
Where it is used
- Blast permits near buildings.
- Delay design to limit vibration.
Common mistakes
- Using total charge instead of charge per delay.
- Applying another site's constants without measurement.
Assumptions and limits
- Empirical regression; wide scatter about the mean line.
Questions and answers
What scaled distance keeps a blast safe?
Regulators use fixed scaled distances such as 50, 55 or 65 ft/lb½, statistically shown to keep vibration below the usual limits.
Why does the charge per delay matter and not the total?
Delays separate the detonations so each wave arrives alone; the largest charge firing within about 8 ms sets the vibration.
What do the defaults represent?
500 lb per delay at 1,500 ft: scaled distance 67 ft/lb½ and a predicted 0.16 in/s with the USBM vertical average; a 55 ft/lb½ limit allows 744 lb per delay.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Dougherty and Schissler (eds.), SME Mining Reference Handbook, 2nd ed. (SME, 2020), ch. 11, eqs. 11.51-11.52 and Table 11.8 (Siskind et al., USBM RI 8507, 1980)