Worked example
Example: 6.75 in ANFO hole, 30 ft bench, 1.0 lb/yd3, rectangular. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Blasthole diameter | 6.7500 in |
| Explosive density (specific gravity) | 0.85000 - |
| Bench height | 30.000 ft |
| Powder factor (explosive per bank volume) | 1.0000 lb/yd³ |
| Pattern | Rectangular, S = 1.5B |
Applying the formula below gives:
| Result | Value |
|---|---|
| Load factor (explosive per length of hole) | 13.187 lb/ft |
| Stemming | 13.500 ft |
| Subdrill | 4.5000 ft |
| Powder column | 21.000 ft |
| Explosive per hole | 276.92 lb |
| Rock broken per hole | 276.92 yd³ |
| Burden | 12.890 ft |
| Spacing | 19.335 ft |
Open this example in the calculator and change any input.
Formula
\(LF = 0.34\,SG_eD_e^2, \quad T = 24D_e, \quad J = \tfrac13T, \quad C = H + J - T\)
\(W_E = C\cdot LF, \quad V_r = \frac{W_E}{P_f}, \quad B = \sqrt{\frac{V_r}{kH}},\ S = kB\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D_e\) | Blasthole diameter | m |
| \(SG_e\) | Explosive density (specific gravity) | - |
| \(H\) | Bench height | m |
| \(P_f\) | Powder factor (explosive per bank volume) | kg/m³ |
| \(\text{pattern}\) | Pattern | - |
| \(LF\) | Load factor (explosive per length of hole) | kg/m |
| \(T\) | Stemming | m |
| \(J\) | Subdrill | m |
| \(C\) | Powder column | m |
| \(W_E\) | Explosive per hole | kg |
| \(V_r\) | Rock broken per hole | m³ |
| \(B\) | Burden | m |
| \(S\) | Spacing | m |
Method and standards
Powder factor method.
Where it is used
- First blast pattern for a new bench or rock type.
- Checking what a change of hole size does to the pattern.
Common mistakes
- Using the hole depth instead of the bench height for H.
- Mixing powder factor per short ton with per cubic yard.
Assumptions and limits
- Empirical; adjust burden for geology and confinement.
Questions and answers
Which powder factor should I choose?
Designers quote 0.25-0.40 lb/yd³ for easy breakage, 0.40-0.75 medium, 0.75-1.25 hard and 1.25-2.50 very hard rock; the seismic velocity of the rock is another guide.
Why is the load factor 0.34 SG D²?
It is the mass of explosive in one foot of a hole of D inches filled at specific gravity SG: π/4 × D² in² × 12 in × 0.0361 lb/in³ × SG.
What do the defaults represent?
A 6¾ in hole on a 30 ft bench loaded with ANFO (SG 0.85) for 1 lb/yd³: 13.2 lb/ft, 13.5 ft of stemming, 4.5 ft of subdrill and a 21 ft column, so 277 lb per hole breaking 277 yd³ on a 12.9 ft by 19.3 ft rectangular pattern.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Dougherty and Schissler (eds.), SME Mining Reference Handbook, 2nd ed. (SME, 2020), ch. 11, eqs. 11.1-11.10 (powder factor method)