FireCADCalc

Compressibility Factor by the Pitzer Virial Correlation (Abbott)

Compressibility factor Z and gas density of a pure gas from reduced temperature and pressure by the Pitzer generalised second-virial correlation (Abbott).

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: Propane 400 K, 20 barMethane 300 K, 30 barCO2 350 K, 10 bar

From a property table for the gas.

Results

Reduced temperature1.5743
Reduced pressure0.65232
B⁰ = 0.083 − 0.422/T_r^1.6-0.12116
B¹ = 0.139 − 0.172/T_r^4.20.11343
Compressibility factor0.95031
Density20.304kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Propane 400 K, 20 bar. The inputs, in the units selected above:

InputValue
Temperature126.85 °C
Pressure (absolute)20.000 bar
Critical temperature96.650 °C
Critical pressure42.480 bar
Acentric factor0.15200 -
Molar mass44.097 kg/kmol

Applying the formula below gives:

ResultValue
Reduced temperature1.0817
Reduced pressure0.47081
B⁰ = 0.083 − 0.422/T_r^1.6-0.28919
B¹ = 0.139 − 0.172/T_r^4.20.015309
Compressibility factor0.87514
Density30.302 kg/m³

Open this example in the calculator and change any input.

Formula

\(Z = 1 + \left(B^0 + \omega B^1\right)\frac{p_r}{T_r}, \quad B^0 = 0.083 - \frac{0.422}{T_r^{1.6}}, \quad B^1 = 0.139 - \frac{0.172}{T_r^{4.2}}\)

Variables

Symbol Meaning SI unit
\(T\) Temperature K
\(p\) Pressure (absolute) Pa
\(T_c\) Critical temperature K
\(p_c\) Critical pressure Pa
\(\omega\) Acentric factor -
\(M\) Molar mass kg/kmol
\(T_r\) Reduced temperature -
\(p_r\) Reduced pressure -
\(B^0\) B⁰ = 0.083 − 0.422/T_r1.6 -
\(B^1\) B¹ = 0.139 − 0.172/T_r4.2 -
\(Z\) Compressibility factor -
\(\rho\) Density kg/m³

Method and standards

Pitzer–Abbott.

Where it is used

  • Gas metering and compressor calculations.
  • Fuel gas density at line pressure.

Common mistakes

  • Using it for liquids.
  • Gauge pressure.

Assumptions and limits

  • Non-polar or slightly polar gases.
  • Gas phase only. No phase check is made: below the critical temperature make sure the pressure is below the vapour pressure, or the result is meaningless.

References

  • Pitzer generalised second-virial correlation with the Abbott equations (Smith, Van Ness and Abbott, Introduction to Chemical Engineering Thermodynamics)

Questions and answers

Propane at 400 K and 20 bar?

Z about 0.875.

When is it valid?

Gases at low to moderate reduced pressure; near saturation or high pressure use a cubic equation.

Polar gases?

Errors grow for strongly polar or hydrogen-bonding gases.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.