FireCADCalc

Tunnel Kiln Heat Balance and Fuel per kg of Ware

Heat to fire ceramic ware in a tunnel kiln (ware, firing reactions and kiln cars) with losses, and the fuel per kg of fired ware.

Inputs

Examples: Illustrative tile kiln on gasSanitaryware, heavy carsBrick tunnel kiln, coal

Accepted: 0.36 to 360,000 kg/h
Accepted: 0.5 to 2 kJ/(kg·K)
Accepted: 526.85 to 1,726.8 °C
Accepted: 0 to 226.85 °C
Accepted: 0 to 326.85 °C
Accepted: 0 to 2,000 kJ/kg
Accepted: 0 to 10
Accepted: 0.5 to 1.5 kJ/(kg·K)
Accepted: 0 to 326.85 °C
Accepted: 0 to 90 %
Accepted: 10,000 to 60,000 kJ/kg

Results

In a tunnel kiln the ware is heated to firing temperature and cooled again in counterflow with the combustion air, so most of its sensible heat is recovered: what remains is the heat it carries out at the exit and the heat absorbed by firing reactions (dehydroxylation of clay, decomposition of carbonates, less any exothermic oxidation). Kiln cars and furniture also leave warm. Flue gas and wall losses usually take half or more of the fuel heat. Typical totals are 1.5–3 MJ per kg of ware for heavy clay and tiles, more for sanitaryware and porcelain.

Ware heat (net of heat recovered in the cooling zone)450.00kJ/kg
Car heat carried out105.00kJ/kg
Fuel heat per kg of ware1,233.3kJ/kg
Fuel rate52.482kg/h
Fuel per kg of ware0.026241

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative tile kiln on gas. The inputs, in the units selected above:

InputValue
Fired ware output2,000.0 kg/h
Mean specific heat of the ware1.0000 kJ/(kg·K)
Firing temperature1,200.0 °C
Ware entry temperature30.000 °C
Ware exit temperature80.000 °C
Heat of firing reactions per kg of ware400.00 kJ/kg
Kiln car and furniture mass per kg of ware1.5000 -
Specific heat of cars and furniture1.0000 kJ/(kg·K)
Car exit temperature100.00 °C
Flue gas and wall losses as a share of fuel heat55.000 %
Fuel net calorific value47,000 kJ/kg

Applying the formula below gives:

ResultValue
Ware heat (net of heat recovered in the cooling zone)450.00 kJ/kg
Car heat carried out105.00 kJ/kg
Fuel heat per kg of ware1,233.3 kJ/kg
Fuel rate52.482 kg/h
Fuel per kg of ware0.026241

Open this example in the calculator and change any input.

Formula

\(q = \frac{c_w(T_{out} - T_{in}) + h_r + r_c c_c (T_c - T_{in})}{1 - f_L}, \quad \dot m_{fuel} = \frac{q\,\dot m_w}{NCV}\)

Variables

Symbol Meaning SI unit
\(\dot m_w\) Fired ware output kg/s
\(c_w\) Mean specific heat of the ware J/(kg·K)
\(T_{fire}\) Firing temperature K
\(T_{in}\) Ware entry temperature K
\(T_{out}\) Ware exit temperature K
\(h_r\) Heat of firing reactions per kg of ware J/kg
\(r_c\) Kiln car and furniture mass per kg of ware -
\(c_c\) Specific heat of cars and furniture J/(kg·K)
\(T_{c}\) Car exit temperature K
\(f_L\) Flue gas and wall losses as a share of fuel heat -
\(NCV\) Fuel net calorific value J/kg
\(q_w\) Ware heat (net of heat recovered in the cooling zone) J/kg
\(q_c\) Car heat carried out J/kg
\(q\) Fuel heat per kg of ware J/kg
\(\dot m_{fuel}\) Fuel rate kg/s
\(m_{fuel}/m_w\) Fuel per kg of ware -

Method and standards

Tunnel kiln.

Where it is used

  • Tile, brick, sanitaryware and refractory kilns.
  • Energy audits of ceramic plants.

Common mistakes

  • Counting the full ware sensible heat to firing temperature.
  • Ignoring the kiln cars.

Assumptions and limits

  • Steady operation; losses as a share of fuel heat.

References

  • Heat balance of a counterflow tunnel kiln

Questions and answers

Why is the ware's own sensible heat small?

In counterflow the cooling ware preheats the combustion air, so only its exit heat is lost.

What is the biggest loss?

Usually the flue gas leaving the preheating zone, then the structure and the kiln cars.

What do the defaults represent?

An illustrative kiln firing 2 t/h of ware at 1200 °C on natural gas, 1.5 kg of cars per kg of ware, 55 % losses.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mullinger and Jenkins, Industrial and Process Furnaces, 2nd ed. (Butterworth-Heinemann, 2014), Reed, Principles of Ceramics Processing, 2nd ed. (Wiley, 1995)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.