Worked example
Example: Illustrative tile kiln on gas. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fired ware output | 2,000.0 kg/h |
| Mean specific heat of the ware | 1.0000 kJ/(kg·K) |
| Firing temperature | 1,200.0 °C |
| Ware entry temperature | 30.000 °C |
| Ware exit temperature | 80.000 °C |
| Heat of firing reactions per kg of ware | 400.00 kJ/kg |
| Kiln car and furniture mass per kg of ware | 1.5000 - |
| Specific heat of cars and furniture | 1.0000 kJ/(kg·K) |
| Car exit temperature | 100.00 °C |
| Flue gas and wall losses as a share of fuel heat | 55.000 % |
| Fuel net calorific value | 47,000 kJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Ware heat (net of heat recovered in the cooling zone) | 450.00 kJ/kg |
| Car heat carried out | 105.00 kJ/kg |
| Fuel heat per kg of ware | 1,233.3 kJ/kg |
| Fuel rate | 52.482 kg/h |
| Fuel per kg of ware | 0.026241 |
Open this example in the calculator and change any input.
Formula
\(q = \frac{c_w(T_{out} - T_{in}) + h_r + r_c c_c (T_c - T_{in})}{1 - f_L}, \quad \dot m_{fuel} = \frac{q\,\dot m_w}{NCV}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_w\) | Fired ware output | kg/s |
| \(c_w\) | Mean specific heat of the ware | J/(kg·K) |
| \(T_{fire}\) | Firing temperature | K |
| \(T_{in}\) | Ware entry temperature | K |
| \(T_{out}\) | Ware exit temperature | K |
| \(h_r\) | Heat of firing reactions per kg of ware | J/kg |
| \(r_c\) | Kiln car and furniture mass per kg of ware | - |
| \(c_c\) | Specific heat of cars and furniture | J/(kg·K) |
| \(T_{c}\) | Car exit temperature | K |
| \(f_L\) | Flue gas and wall losses as a share of fuel heat | - |
| \(NCV\) | Fuel net calorific value | J/kg |
| \(q_w\) | Ware heat (net of heat recovered in the cooling zone) | J/kg |
| \(q_c\) | Car heat carried out | J/kg |
| \(q\) | Fuel heat per kg of ware | J/kg |
| \(\dot m_{fuel}\) | Fuel rate | kg/s |
| \(m_{fuel}/m_w\) | Fuel per kg of ware | - |
Method and standards
Tunnel kiln.
Where it is used
- Tile, brick, sanitaryware and refractory kilns.
- Energy audits of ceramic plants.
Common mistakes
- Counting the full ware sensible heat to firing temperature.
- Ignoring the kiln cars.
Assumptions and limits
- Steady operation; losses as a share of fuel heat.
References
- Heat balance of a counterflow tunnel kiln
Questions and answers
Why is the ware's own sensible heat small?
In counterflow the cooling ware preheats the combustion air, so only its exit heat is lost.
What is the biggest loss?
Usually the flue gas leaving the preheating zone, then the structure and the kiln cars.
What do the defaults represent?
An illustrative kiln firing 2 t/h of ware at 1200 °C on natural gas, 1.5 kg of cars per kg of ware, 55 % losses.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mullinger and Jenkins, Industrial and Process Furnaces, 2nd ed. (Butterworth-Heinemann, 2014), Reed, Principles of Ceramics Processing, 2nd ed. (Wiley, 1995)