Worked example
Example: 380 kg/h O2, 50 kW agitation. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Oxygen uptake of the whole broth | 380.00 kg/h |
| Heat released per mol O₂ (enter as a positive number) | 460.00 kJ/mol |
| Agitation power to the broth | 50.000 kW |
| Cooling-water temperature rise | 5.0000 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Metabolic heat | 1,517.5 kW |
| Total heat to remove | 1,567.5 kW |
| Cooling-water flow | 269.61 t/h |
Open this example in the calculator and change any input.
Formula
\(Q_{met} = \frac{\dot m_{O_2}}{M_{O_2}}\Delta H_{O_2}, \quad Q = Q_{met} + P_{ag}, \quad \dot m_w = \frac{Q}{c_p\Delta T_w}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_{O_2}\) | Oxygen uptake of the whole broth | kg/s |
| \(\Delta H_{O_2}\) | Heat released per mol O₂ (enter as a positive number) | J/mol |
| \(M_{O_2}\) | Molar mass of oxygen, 0.031998 kg/mol | kg/mol |
| \(c_p\) | Specific heat of cooling water, 4186 J/(kg·K) | J/(kg·K) |
| \(P_{ag}\) | Agitation power to the broth | W |
| \(\Delta T_w\) | Cooling-water temperature rise | K |
| \(Q_{met}\) | Metabolic heat | W |
| \(Q\) | Total heat to remove | W |
| \(\dot m_w\) | Cooling-water flow | kg/s |
Method and standards
Heat balance.
Where it is used
- Aerobic fermenter cooling design.
- Yeast propagation and single-cell protein plants.
Common mistakes
- Forgetting agitation power.
- Using the anaerobic figure for aerobic culture.
Assumptions and limits
- Steady state.
- Doran's −460 kJ/mol O₂ is a heat of reaction (negative = released); enter it here as +460 kJ/mol, the heat released.
References
- Doran
- Bioprocess Engineering Principles
- 2nd ed. (Academic Press, 2013)
- ch. 5 (heat of reaction from oxygen consumption, about −460 kJ/mol O₂)
- Cooney
- Wang and Wang (1969)
- Biotechnol. Bioeng. 11: 269
Questions and answers
Why is heat tied to oxygen?
Respiration oxidises substrate with oxygen; per mole of oxygen the heat released is nearly the same for most substrates.
Is this for ethanol fermentation?
No: anaerobic ethanol fermentation uses the sugar-based heat in the fermentation cooling calculator.
What do the defaults give?
380 kg/h of oxygen plus 50 kW agitation: about 1.57 MW, 270 t/h of cooling water at 5 K rise.