FireCADCalc

Electric Vehicle Fleet Charging Energy and Demand

Daily charging energy, average power over the charging window, peak demand with diversity and number of chargers needed for a fleet of electric vehicles.

Thermal power plant

Inputs

Examples: Illustrative 50 vans, 22 kW chargers, 8 hBus depot 30 buses, 150 kWSmall fleet 5 cars, 7 kW

Accepted: 1 to 100,000
Accepted: 1 to 2,000 km
Accepted: 2.7778 to 2,777.8 Wh/km
Accepted: 50 to 100 %
Accepted: 0.16667 to 24 h
Accepted: 1 to 1,000 kW
Accepted: 10 to 100 %

Results

Energy = N·d·e/η; chargers so that energy fits the window; peak = chargers × power × diversity (not below the average). Smart charging can flatten the peak towards the average power.

Grid energy per day0.054545MWh
Average power over the window5.4545kW
Chargers needed (each runs the whole window)1.0000
Peak demand with diversity7.0000kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 50 vans, 22 kW chargers, 8 h. The inputs, in the units selected above:

InputValue
Vehicles50.000 -
Distance per vehicle per day180.00 km
Consumption at the wheels from the battery220.00 Wh/km
Charging efficiency (grid to battery)90.000 %
Charging window8.0000 h
Charger power22.000 kW
Diversity factor (share charging at once)80.000 %

Applying the formula below gives:

ResultValue
Grid energy per day2.2000 MWh
Average power over the window275.00 kW
Chargers needed (each runs the whole window)13.000
Peak demand with diversity275.00 kW

Open this example in the calculator and change any input.

Formula

\(E = \frac{Nde}{\eta_c}, \quad n_c = \left\lceil\frac{E}{P_ct_w}\right\rceil, \quad P_{pk} = n_cP_ck_d\)

Variables

Symbol Meaning SI unit
\(N\) Vehicles -
\(d\) Distance per vehicle per day m
\(e\) Consumption at the wheels from the battery J/m
\(\eta_c\) Charging efficiency (grid to battery) -
\(t_w\) Charging window s
\(P_c\) Charger power W
\(k_d\) Diversity factor (share charging at once) -
\(E\) Grid energy per day J
\(\bar P\) Average power over the window W
\(n_c\) Chargers needed (each runs the whole window) -
\(P_{pk}\) Peak demand with diversity W

Method and standards

Fleet charging.

Where it is used

  • Depot electrification planning.
  • Grid connection applications.

Common mistakes

  • Forgetting charging losses.
  • Assuming all chargers run at full power all night.

Assumptions and limits

  • Daily average duty; one charging window.

References

  • Fleet charging energy balance

Questions and answers

How much power does a depot need?

Total daily energy over the charging window sets the average; diversity and smart charging decide how far the peak rises above it.

Why use diversity?

Not every vehicle charges at full power at the same time; batteries arrive at different states of charge and taper near full.

What do the defaults represent?

An illustrative fleet of 50 vans, 180 km a day each at 220 Wh/km, 90 % charging efficiency, an 8-hour overnight window and 22 kW chargers with 80 % diversity.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.