Worked example
Example: Cane diffuser, draft 1.1. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Draft ratio (juice drawn per juice entering with the solids) | 1.1000 - |
| Transfer units ΔL of the diffuser | 15.000 - |
| Extraction of a mill ahead of the diffuser (0 for a cane diffuser) | 0 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Sugar left per sugar entering | 3.0290 % |
| Diffuser extraction | 96.971 % |
| Overall extraction | 96.971 % |
Open this example in the calculator and change any input.
Formula
\(\frac{\varepsilon}{Z_0} = \frac{(q - 1)e^{-(q-1)N/q}}{q - e^{-(q-1)N/q}}, \quad E_d = 1 - \frac{\varepsilon}{Z_0}, \quad E = e_m + (1 - e_m)E_d\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(q\) | Draft ratio (juice drawn per juice entering with the solids) | - |
| \(N\) | Transfer units ΔL of the diffuser | - |
| \(e_m\) | Extraction of a mill ahead of the diffuser (0 for a cane diffuser) | - |
| \(\varepsilon/Z_0\) | Sugar left per sugar entering | - |
| \(E_d\) | Diffuser extraction | - |
| \(E\) | Overall extraction | - |
Method and standards
Hugot's counter-current diffusion theory.
Where it is used
- Judging the effect of draft on extraction.
- Comparing cane and bagasse diffusion.
Common mistakes
- Using draft on cane where draft on juice is meant.
- Expecting the theory to give absolute values without calibration.
Assumptions and limits
- Ideal counter-current stages; calibrate N from plant results (it has no direct physical input).
- Draft here is Hugot's theoretical ratio, juice drawn per juice entering with the solids. The diffuser draft balance calculator uses draft per cane (draft juice % cane); the two are not the same number.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 23
- counter-current theory
- eqns 23.5–23.12
- pp. 361–366
- and p. 368
Questions and answers
What is draft?
The weight of juice drawn from the diffuser per weight of juice entering with the cane; it must exceed 1 for counter-current extraction to work.
Why does extraction rise steeply with draft near 1?
With little excess liquid, the last stages see almost no concentration difference to drive diffusion.
What are transfer units?
A measure of the contact the diffuser gives (Hugot's ΔL): longer beds, slower travel and better preparation raise it.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.