Worked example
Example: 250 TCH, draft 105 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 250.00 t/h |
| Fibre % cane | 14.500 % |
| Brix % cane | 16.000 % |
| Brix extraction | 97.500 % |
| Draft (draft juice per cane) | 105.00 % |
| Fibre % final bagasse | 50.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Draft juice | 262.50 t/h |
| Brix of draft juice | 14.857 % |
| Final bagasse | 72.500 t/h |
| Imbibition water | 85.000 t/h |
| Imbibition % fibre | 234.48 % |
Open this example in the calculator and change any input.
Formula
\(J = d A, \quad B_J = \frac{B_c e}{d}, \quad B = \frac{A f}{f'}, \quad W = J + B - A\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Crushing rate | kg/s |
| \(f\) | Fibre % cane | - |
| \(B_c\) | Brix % cane | - |
| \(e\) | Brix extraction | - |
| \(d\) | Draft (draft juice per cane) | - |
| \(f'\) | Fibre % final bagasse | - |
| \(J\) | Draft juice | kg/s |
| \(B_J\) | Brix of draft juice | - |
| \(B\) | Final bagasse | kg/s |
| \(W\) | Imbibition water | kg/s |
| \(W/(A f)\) | Imbibition % fibre | - |
Method and standards
Mass and soluble-solids balance.
Where it is used
- Setting diffuser water.
- Checking juice brix to the evaporators.
Common mistakes
- Using draft % fibre.
- Counting returned press water as imbibition.
Assumptions and limits
- Losses and evaporation neglected.
- Direct steam injected to heat the diffuser condenses into the juice and is not an input; with direct heating W overstates the imbibition water by that condensate.
- Extraction and fibre % bagasse are independent inputs; a note appears when the brix they leave in the bagasse, B_c(1 − e)A/B, exceeds 5 %.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 23
- draft and juice balance (Table 23.3 and pp. 369–380)
- Mass balance: cane + water = draft juice + bagasse (losses neglected)
Questions and answers
Why is draft juice weaker than mill juice?
More water passes through a diffuser; brix of draft juice falls as draft rises.
Does press water count?
Press water from the dewatering mills returns to the diffuser and is inside the balance; only fresh water is W.
Typical imbibition?
Diffusers run 250–350 % on fibre, more than mills.