FireCADCalc

Rectangular Tank Wall: Hydrostatic Force and Bending Moment

Resultant hydrostatic force on a vertical rectangular tank wall, its centre of pressure and the bending moment at the base of a cantilever wall per metre width.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 3 m water, 5 m wallMolasses 4 m, 6 m wall

Results

Cantilever wall fixed at the base and free at the top; walls supported at the sides or top carry less moment (plate theory).

Pressure at the base29.420kPa
Resultant force on the wall220.65kN
Centre of pressure above the base1.0000m
Base moment per metre width of wall, kN·m per m (cantilever)44.130kN·m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 3 m water, 5 m wall. The inputs, in the units selected above:

InputValue
Liquid depth3.0000 m
Wall width5.0000 m
Liquid density1,000.0 kg/m³

Applying the formula below gives:

ResultValue
Pressure at the base29.420 kPa
Resultant force on the wall220.65 kN
Centre of pressure above the base1.0000 m
Base moment per metre width of wall, kN·m per m (cantilever)44.130 kN·m

Open this example in the calculator and change any input.

Formula

\(F = \frac{\rho gH^2b}{2}, \quad y_c = \frac H3, \quad M = \frac{\rho gH^3}{6}\)

Variables

Symbol Meaning SI unit
\(H\) Liquid depth m
\(b\) Wall width m
\(\rho\) Liquid density kg/m³
\(p_{max}\) Pressure at the base Pa
\(F\) Resultant force on the wall N
\(y_c\) Centre of pressure above the base m
\(M\) Base moment per metre width of wall (cantilever) N·m/m

Method and standards

Hydrostatics.

Where it is used

  • Concrete and steel rectangular tanks.
  • Bund and sump walls.

Common mistakes

  • Ignoring surcharge or sloshing.
  • Treating a supported wall as a cantilever (conservative).

Assumptions and limits

  • Static liquid; vertical wall.
  • The base moment is per metre width of wall and is shown in kN·m per metre in every unit system; multiply by the width for the whole wall.

References

  • Hydrostatics (definitions)

Questions and answers

Why is the force at one-third height?

Pressure grows linearly with depth; the triangular load's centroid is a third up from the base.

Why does moment grow so fast?

With depth cubed: doubling depth multiplies the base moment by eight.

What do the defaults represent?

A 3 m deep water tank with a 5 m wall.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.