FireCADCalc

Ship Hull Form Coefficients: Block, Midship, Prismatic, Waterplane

Block, midship, prismatic, waterplane and vertical prismatic coefficients of a hull, with displacement and tonnes per cm immersion, from its dimensions and areas.

Inputs

Examples: Illustrative cargo ship: 120 x 20 x 7.5 m, 12,600 m3Tanker: 240 x 42 x 15 m, 126,000 m3River barge in fresh water: 60 x 12 x 2.5 m

Accepted: 1 to 500 m
Accepted: 0.5 to 80 m
Accepted: 0.1 to 30 m
Accepted: 0.1 to 1,000,000 m³
Accepted: 0.05 to 3,000 m²
Accepted: 0.5 to 40,000 m²
Accepted: 990 to 1,040 kg/m³

Results

C_P = C_B/C_M. Typical C_B: tankers 0.80–0.85, bulk carriers 0.75–0.85, general cargo 0.65–0.75, container ships 0.55–0.70, fast craft below 0.5.

Block coefficient ∇/(LBT)0.83333
Midship coefficient A_M/(BT)0.99365
Prismatic coefficient ∇/(A_M L)0.83866
Waterplane coefficient A_WP/(LB)0.86310
Vertical prismatic coefficient ∇/(A_WP T)0.96552
Displacement ρ∇129,150t
Tonnes per centimetre immersion89.175t/cm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative cargo ship: 120 x 20 x 7.5 m, 12,600 m3. The inputs, in the units selected above:

InputValue
Length between perpendiculars (or waterline)120.00 m
Breadth (moulded)20.000 m
Draught (moulded)7.5000 m
Displaced volume12,600 m³
Midship section area (to the draught)146.00 m²
Waterplane area2,000.0 m²
Water density (sea 1,025; fresh 1,000)1,025.0 kg/m³

Applying the formula below gives:

ResultValue
Block coefficient ∇/(LBT)0.70000
Midship coefficient A_M/(BT)0.97333
Prismatic coefficient ∇/(A_M L)0.71918
Waterplane coefficient A_WP/(LB)0.83333
Vertical prismatic coefficient ∇/(A_WP T)0.84000
Displacement ρ∇12,915 t
Tonnes per centimetre immersion20.500 t/cm

Open this example in the calculator and change any input.

Formula

\(C_B = \frac{\nabla}{LBT}, \quad C_M = \frac{A_M}{BT}, \quad C_P = \frac{\nabla}{A_ML} = \frac{C_B}{C_M}, \quad C_{WP} = \frac{A_{WP}}{LB}\)

\(\Delta = \rho\nabla, \quad TPC = \rho A_{WP} \times 0.01\ \text{m}\)

Variables

Symbol Meaning SI unit
\(L\) Length between perpendiculars (or waterline) m
\(B\) Breadth (moulded) m
\(T\) Draught (moulded) m
\(\nabla\) Displaced volume m³
\(A_M\) Midship section area (to the draught) m²
\(A_{WP}\) Waterplane area m²
\(\rho\) Water density (sea 1,025; fresh 1,000) kg/m³
\(C_B\) Block coefficient ∇/(LBT) -
\(C_M\) Midship coefficient A_M/(BT) -
\(C_P\) Prismatic coefficient ∇/(A_M L) -
\(C_{WP}\) Waterplane coefficient A_WP/(LB) -
\(C_{VP}\) Vertical prismatic coefficient ∇/(A_WP T) -
\(\Delta\) Displacement ρ∇ kg
\(TPC\) Tonnes per centimetre immersion kg/m

Method and standards

Hull form coefficients.

Where it is used

  • Preliminary ship design and comparison of hull forms.
  • Loading calculations and draught changes.

Common mistakes

  • Mixing the waterline length and the length between perpendiculars.
  • Using fresh-water density for a ship at sea.

Assumptions and limits

  • Moulded dimensions; areas to the stated draught.

References

  • Hull form coefficients and tonnes per centimetre immersion

Questions and answers

What does the block coefficient say about a ship?

How full the hull is: a full tanker form (C_B ≈ 0.85) carries much cargo but needs more power per knot; a fine container ship (0.6) is built for speed.

How is TPC used?

To find the change in draught from loading or discharging: 500 t loaded on a ship with TPC 20.5 t/cm sinks it about 24 cm.

What do the defaults represent?

An illustrative 120 m general cargo ship, 20 m beam and 7.5 m draught, displacing 12,600 m³ in sea water.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Rawson and Tupper, Basic Ship Theory, 5th ed. (Butterworth-Heinemann, 2001), ch. 2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.