Worked example
Example: Illustrative cargo ship: 120 x 20 x 7.5 m, 12,600 m3. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Length between perpendiculars (or waterline) | 120.00 m |
| Breadth (moulded) | 20.000 m |
| Draught (moulded) | 7.5000 m |
| Displaced volume | 12,600 m³ |
| Midship section area (to the draught) | 146.00 m² |
| Waterplane area | 2,000.0 m² |
| Water density (sea 1,025; fresh 1,000) | 1,025.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Block coefficient ∇/(LBT) | 0.70000 |
| Midship coefficient A_M/(BT) | 0.97333 |
| Prismatic coefficient ∇/(A_M L) | 0.71918 |
| Waterplane coefficient A_WP/(LB) | 0.83333 |
| Vertical prismatic coefficient ∇/(A_WP T) | 0.84000 |
| Displacement ρ∇ | 12,915 t |
| Tonnes per centimetre immersion | 20.500 t/cm |
Open this example in the calculator and change any input.
Formula
\(C_B = \frac{\nabla}{LBT}, \quad C_M = \frac{A_M}{BT}, \quad C_P = \frac{\nabla}{A_ML} = \frac{C_B}{C_M}, \quad C_{WP} = \frac{A_{WP}}{LB}\)
\(\Delta = \rho\nabla, \quad TPC = \rho A_{WP} \times 0.01\ \text{m}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Length between perpendiculars (or waterline) | m |
| \(B\) | Breadth (moulded) | m |
| \(T\) | Draught (moulded) | m |
| \(\nabla\) | Displaced volume | m³ |
| \(A_M\) | Midship section area (to the draught) | m² |
| \(A_{WP}\) | Waterplane area | m² |
| \(\rho\) | Water density (sea 1,025; fresh 1,000) | kg/m³ |
| \(C_B\) | Block coefficient ∇/(LBT) | - |
| \(C_M\) | Midship coefficient A_M/(BT) | - |
| \(C_P\) | Prismatic coefficient ∇/(A_M L) | - |
| \(C_{WP}\) | Waterplane coefficient A_WP/(LB) | - |
| \(C_{VP}\) | Vertical prismatic coefficient ∇/(A_WP T) | - |
| \(\Delta\) | Displacement ρ∇ | kg |
| \(TPC\) | Tonnes per centimetre immersion | kg/m |
Method and standards
Hull form coefficients.
Where it is used
- Preliminary ship design and comparison of hull forms.
- Loading calculations and draught changes.
Common mistakes
- Mixing the waterline length and the length between perpendiculars.
- Using fresh-water density for a ship at sea.
Assumptions and limits
- Moulded dimensions; areas to the stated draught.
References
- Hull form coefficients and tonnes per centimetre immersion
Questions and answers
What does the block coefficient say about a ship?
How full the hull is: a full tanker form (C_B ≈ 0.85) carries much cargo but needs more power per knot; a fine container ship (0.6) is built for speed.
How is TPC used?
To find the change in draught from loading or discharging: 500 t loaded on a ship with TPC 20.5 t/cm sinks it about 24 cm.
What do the defaults represent?
An illustrative 120 m general cargo ship, 20 m beam and 7.5 m draught, displacing 12,600 m³ in sea water.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Rawson and Tupper, Basic Ship Theory, 5th ed. (Butterworth-Heinemann, 2001), ch. 2