FireCADCalc

Fresh Water Allowance and Dock Water Allowance (Load Line)

Fresh water allowance and dock water allowance of a ship from its displacement and tonnes per centimetre, with the draught change when moving between waters.

Inputs

Examples: Illustrative: 15,000 t, TPC 22 t/cm, dock water 1010Large bulk carrier: 80,000 t, TPC 70, dock water 1005Coaster in fresh water: 3,000 t, TPC 8

Accepted: 1 to 1,000,000 t
Accepted: 0.01 to 10,000 t/cm
Accepted: 1,000 to 1,025 kg/m³

Results

FWA (mm) = Δ (t)/(4 TPC (t/cm)): the sinkage from salt water (1,025) to fresh water (1,000). In dock water of intermediate density the ship may load until the load line is submerged by the DWA.

Fresh water allowance Δ/(4 TPC)93.750mm
Dock water allowance93.750mm
Sinkage from salt to dock water (approximate)93.750mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 15,000 t, TPC 22 t/cm, dock water 1010. The inputs, in the units selected above:

InputValue
Displacement at the summer load line15,000 t
Tonnes per centimetre immersion in salt water22.000 t/cm
Density of the dock water1,010.0 kg/m³

Applying the formula below gives:

ResultValue
Fresh water allowance Δ/(4 TPC)170.45 mm
Dock water allowance102.27 mm
Sinkage from salt to dock water (approximate)102.27 mm

Open this example in the calculator and change any input.

Formula

\(FWA = \frac{\Delta}{4\,TPC}\ \text{mm} \;(\Delta\ \text{in t}, TPC\ \text{in t/cm}), \quad DWA = FWA\,\frac{1025 - \rho_{dock}}{25}\)

Variables

Symbol Meaning SI unit
\(\Delta\) Displacement at the summer load line kg
\(TPC\) Tonnes per centimetre immersion in salt water kg/m
\(\rho_{dock}\) Density of the dock water kg/m³
\(FWA\) Fresh water allowance Δ/(4 TPC) m
\(DWA\) Dock water allowance m
\(\delta T\) Sinkage from salt to dock water (approximate) m

Method and standards

Load line allowances.

Where it is used

  • Cargo planning in estuary and river ports.
  • Load line surveys and port state checks.

Common mistakes

  • Using the fresh-water TPC.
  • Forgetting the DWA when loading in brackish water.

Assumptions and limits

  • Wall-sided ship near the waterline.

References

  • Fresh and dock water allowances

Questions and answers

Why does a ship sink deeper in fresh water?

Fresh water is about 2.5 % less dense, so the ship must displace 2.5 % more volume to support the same weight.

How is the DWA used when loading in a river port?

The ship may load until the appropriate load line is submerged by the DWA, so that it rises to the mark when it reaches salt water.

What do the defaults represent?

An illustrative 15,000 t ship with a TPC of 22 t/cm loading in dock water of 1,010 kg/m³.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Barrass and Derrett, Ship Stability for Masters and Mates, 7th ed. (Butterworth-Heinemann, 2012), ch. 4

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.