Worked example
Example: Illustrative 1.5 t HHP anchor, 25 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Anchor mass | 1,500.0 kg |
| Anchor holding power ratio (holding/weight) | 7.0000 - |
| Chain mass per metre (in air) | 50.000 kg/m |
| Chain length lying on the seabed | 60.000 m |
| Chain–seabed friction coefficient | 0.75000 - |
| Water depth plus fairlead height | 25.000 m |
| Horizontal design load | 150.00 kN |
Applying the formula below gives:
| Result | Value |
|---|---|
| Anchor holding | 89.525 kN |
| Chain friction on the seabed | 19.184 kN |
| Total holding | 108.71 kN |
| Suspended chain length needed | 134.97 m |
| Chain tension at the fairlead | 160.66 kN |
| Scope ratio | 7.7989 |
Open this example in the calculator and change any input.
Formula
\(H = E_am_ag' + \mu_cw L_g, \quad s = \sqrt{h^2 + 2h\frac{T_H}{w}}, \quad T_{top} = T_H + wh\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m_a\) | Anchor mass | kg |
| \(E_a\) | Anchor holding power ratio (holding/weight) | - |
| \(m_c\) | Chain mass per metre (in air) | kg/m |
| \(L_g\) | Chain length lying on the seabed | m |
| \(\mu_c\) | Chain–seabed friction coefficient | - |
| \(h\) | Water depth plus fairlead height | m |
| \(T_H\) | Horizontal design load | N |
| \(H_a\) | Anchor holding | N |
| \(H_c\) | Chain friction on the seabed | N |
| \(H\) | Total holding | N |
| \(s\) | Suspended chain length needed | m |
| \(T_{top}\) | Chain tension at the fairlead | N |
| \((s + L_g)/h\) | Scope ratio | - |
Method and standards
Anchoring.
Where it is used
- Anchoring and mooring of small ships and barges.
- Temporary moorings for marine works.
Common mistakes
- Using weight in air.
- Short scope lifting the anchor shank.
Assumptions and limits
- Uniform chain; steel in seawater; no seabed slope or current on the chain.
References
- Catenary mooring line statics
Questions and answers
Why must the pull be horizontal at the anchor?
Drag anchors lose most of their holding if lifted; enough chain keeps the shank on the seabed.
What is a good scope?
Commonly 5–7 times the depth for anchoring and more in bad weather; the catenary result shows the minimum for the load.
What do the defaults represent?
An illustrative 1.5 t high-holding-power anchor (ratio 7) with 50 kg/m chain, 60 m on the seabed, 25 m depth, 150 kN horizontal load.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Barltrop (ed.), Floating Structures: A Guide for Design and Analysis (OPL, 1998)