FireCADCalc

Admiralty Coefficient: Ship Power at a New Speed or Displacement

Admiralty coefficient of a ship from a known power, displacement and speed, and the power needed at another speed or displacement, assuming the same coefficient.

Inputs

Examples: Illustrative: 20,000 t at 14 kn needs 6,000 kW; 17,000 t at 15 knSlow steaming: 80,000 t container ship from 22 to 18 knLoaded versus ballast: 50,000 to 30,000 t at 13 kn

Accepted: 1 to 1,000,000 t
Accepted: 0.19438 to 77.754 kn
Accepted: 0.001 to 1,000,000 kW
Accepted: 1 to 1,000,000 t
Accepted: 0.19438 to 77.754 kn

Results

P ∝ Δ^(2/3)V³ holds for small changes of speed and displacement of the same ship. Over wide speed ranges the exponent of V rises above 3 as wave resistance grows.

Admiralty coefficient Δ^{2/3}V³/P (t, kn, kW)494.24
Power at the new condition21,908kW
Power ratio0.54771
Fuel per distance ratio (P/V)0.66942

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 20,000 t at 14 kn needs 6,000 kW; 17,000 t at 15 kn. The inputs, in the units selected above:

InputValue
Known displacement20,000 t
Known speed14.000 kn
Known shaft power6,000.0 kW
New displacement17,000 t
New speed15.000 kn

Applying the formula below gives:

ResultValue
Admiralty coefficient Δ^{2/3}V³/P (t, kn, kW)336.97
Power at the new condition6,622.0 kW
Power ratio1.1037
Fuel per distance ratio (P/V)1.0301

Open this example in the calculator and change any input.

Formula

\(C_{adm} = \frac{\Delta^{2/3}V^3}{P}, \quad P_2 = P_1\left(\frac{\Delta_2}{\Delta_1}\right)^{2/3}\left(\frac{V_2}{V_1}\right)^3\)

Variables

Symbol Meaning SI unit
\(\Delta_1\) Known displacement kg
\(V_1\) Known speed m/s
\(P_1\) Known shaft power W
\(\Delta_2\) New displacement kg
\(V_2\) New speed m/s
\(C_{adm}\) Admiralty coefficient Δ^{2/3}V³/P (t, kn, kW) -
\(P_2\) Power at the new condition W
\(P_2/P_1\) Power ratio -
\(F_2/F_1\) Fuel per distance ratio (P/V) -

Method and standards

Admiralty coefficient scaling.

Where it is used

  • Voyage planning, slow steaming and charter speed–consumption estimates.
  • Preliminary powering from a similar ship.

Common mistakes

  • Extrapolating far beyond the known speed.
  • Comparing coefficients computed in different units.

Assumptions and limits

  • Same ship or a close sister; calm water; similar trim.

References

  • Admiralty coefficient method

Questions and answers

How much fuel does slow steaming save?

Fuel per day goes roughly as V³ and fuel per mile as V²: a 10 % speed cut saves about 19 % of fuel per mile.

Why use Δ^(2/3)?

It stands for the wetted surface, which scales with displacement to the two-thirds power for geometrically similar hulls.

What do the defaults represent?

An illustrative 20,000 t ship needing 6,000 kW at 14 knots, re-estimated at 17,000 t and 15 knots.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Barrass and Derrett, Ship Stability for Masters and Mates, 7th ed. (Butterworth-Heinemann, 2012), ch. 37, Rawson and Tupper, Basic Ship Theory, 5th ed. (Butterworth-Heinemann, 2001), ch. 9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.