FireCADCalc

Fan Temperature Rise

Temperature rise of air or gas through a fan from its pressure rise, density, specific heat and efficiency, and the outlet temperature.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserFan and blower

Inputs

Examples: FD fan 3 kPa, 1.15 kg/m³, 80 %ID fan 3 kPa, 0.85 kg/m³, 78 %PA fan 12 kPa, 1.1 kg/m³, 82 %

Air about 1.006 kJ/(kg·K); flue gas about 1.05–1.10 kJ/(kg·K).

Results

Temperature rise through the fan4.1897K
Outlet temperature144.19°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: FD fan 3 kPa, 1.15 kg/m³, 80 %. The inputs, in the units selected above:

InputValue
Fan total pressure rise305.91 mmWC
Gas density at the inlet1.1500 kg/m³
Specific heat of the gas1.0060 kJ/(kg·K)
Fan efficiency80.000 %
Inlet temperature35.000 °C

Applying the formula below gives:

ResultValue
Temperature rise through the fan3.2414 K
Outlet temperature38.241 °C

Open this example in the calculator and change any input.

Formula

\(\Delta T = \frac{\Delta p}{\rho\,c_p\,\eta_f} \qquad T_2 = T_1 + \Delta T\)

Variables

Symbol Meaning SI unit
\(\Delta p\) fan total pressure rise Pa
\(\rho\) gas density at the inlet kg/m³
\(c_p\) specific heat of the gas J/(kg·K)
\(\eta_f\) fan efficiency –
\(T_1\) inlet temperature K
\(\Delta T\) temperature rise K
\(T_2\) outlet temperature K

Method and standards

Energy balance on the fan: all the shaft power ends up in the gas, as useful pressure rise and as heat from the losses. With air power \(\dot V\Delta p\) and shaft power \(\dot V\Delta p/\eta\), the gas gains \(\Delta p/(\rho\eta)\) per kg.

Where it is used

  • Checking gas temperature after fans.
  • Energy balance of recirculation fans.
  • Explaining temperature rise across a fan.

Common mistakes

  • Treating fan heat as a loss when it goes into the gas.
  • Using total pressure with static efficiency.
  • Forgetting motor heat for in-stream motors.

Assumptions and limits

  • Adiabatic fan casing; bearing losses outside the gas stream are included (conservative).
  • Incompressible; for blowers above about 20 kPa use the isentropic relation instead (flagged).

References

  • Energy balance on the fan (ISO 5801 power definitions)

Questions and answers

How much does a fan heat the air?

ΔT = Δp/(ρ·c_p·η). An FD fan at 3 kPa and 80 % warms air by about 3 K; a PA fan at 12 kPa by about 13 K.

Why does it matter?

The warmer air needs more volume downstream and changes the air heater duty; for high-pressure blowers the outlet temperature can limit duct and seal materials.

Which pressure do I use?

The fan total pressure rise with the total efficiency.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.