Single-Flash Geothermal Power Plant Output and Utilisation

Separator steam fraction, turbine exhaust state by the Baumann rule, gross and electrical power, specific output and exergy utilisation of a single-flash plant.

Thermal power plant

Inputs

Examples: Illustrative 250 C reservoir, 160 C separator, 50 C condenser, 100 kg/sHot 300 C reservoir, 180 C separator, 45 C condenserModerate 200 C reservoir, 130 C separator, 55 C condenser

Accepted: 106.85 to 346.85 °C
Accepted: 56.85 to 326.85 °C
Accepted: 16.85 to 126.85 °C
Accepted: 360 to 18,000,000 kg/h
Accepted: 50 to 100 %
Accepted: 80 to 100 %
Accepted: 0.01 to 46.85 °C

Results

Isenthalpic flash to the separator; dry saturated steam to the turbine; Baumann rule η_tw = η_td(1 + x₅)/2 solved in closed form for the exhaust enthalpy. Utilisation efficiency is the electrical output over the exergy of the reservoir liquid relative to saturated liquid at T₀. Parasitic loads (pumps, fans, gas extraction) are not deducted. Water and steam properties from IAPWS-IF97.

Steam fraction after flashing28.877%
Steam flow to the turbine207,911kg/h
Turbine exhaust quality85.210%
Wet turbine efficiency78.714%
Turbine power31.697MW
Electrical power31.063MW
Electrical output per kg of geofluid155.31kJ/kg
Utilisation (exergy) efficiency40.977%
Condenser heat117.81MW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 250 C reservoir, 160 C separator, 50 C condenser, 100 kg/s. The inputs, in the units selected above:

InputValue
Reservoir temperature (saturated liquid)250.00 °C
Separator temperature160.00 °C
Condenser temperature50.000 °C
Total geofluid flow360,000 kg/h
Dry turbine efficiency85.000 %
Generator efficiency98.000 %
Dead-state (ambient) temperature25.000 °C

Applying the formula below gives:

ResultValue
Steam fraction after flashing19.699 %
Steam flow to the turbine70,918 kg/h
Turbine exhaust quality87.124 %
Wet turbine efficiency79.528 %
Turbine power9.3145 MW
Electrical power9.1282 MW
Electrical output per kg of geofluid91.282 kJ/kg
Utilisation (exergy) efficiency35.450 %
Condenser heat40.881 MW

Open this example in the calculator and change any input.

Formula

\(x_2 = \frac{h_1 - h_f(T_{sep})}{h_{fg}(T_{sep})}, \quad h_5 = \frac{h_4 - A\left(1 - \frac{h_6}{h_7 - h_6}\right)}{1 + \frac{A}{h_7 - h_6}}, \quad A = \frac{\eta_{td}}{2}(h_4 - h_{5s}), \quad \eta_u = \frac{\dot W_e}{\dot m e_1}\)

Variables

Symbol Meaning SI unit
\(T_{res}\) Reservoir temperature (saturated liquid) K
\(T_{sep}\) Separator temperature K
\(T_{cond}\) Condenser temperature K
\(\dot m\) Total geofluid flow kg/s
\(\eta_{td}\) Dry turbine efficiency -
\(\eta_g\) Generator efficiency -
\(T_0\) Dead-state (ambient) temperature K
\(x_2\) Steam fraction after flashing -
\(\dot m_s\) Steam flow to the turbine kg/s
\(x_5\) Turbine exhaust quality -
\(\eta_{tw}\) Wet turbine efficiency -
\(\dot W_t\) Turbine power W
\(\dot W_e\) Electrical power W
\(w\) Electrical output per kg of geofluid J/kg
\(\eta_u\) Utilisation (exergy) efficiency -
\(\dot Q_c\) Condenser heat W

Method and standards

Single-flash cycle.

Where it is used

  • Geothermal field development and plant sizing.
  • Checking vendor heat balances.

Common mistakes

  • Using a dry-turbine efficiency for wet expansion.
  • Taking the reservoir temperature as the separator temperature.

Assumptions and limits

  • Saturated-liquid reservoir; no non-condensable gases; no pressure losses in pipes.

References

  • Single-flash cycle with Baumann wet-turbine rule and exergy utilisation

Questions and answers

Why is only part of the geofluid used as steam?

Flashing hot brine at a lower pressure turns only a fraction (often 15–25 %) to steam; the rest is reinjected or flashed again in a double-flash plant.

What utilisation efficiency do flash plants reach?

About 30–45 % of the geofluid exergy; double-flash plants gain another 15–25 % of output.

What do the defaults represent?

An illustrative 250 °C liquid reservoir, separator at 160 °C, condenser at 50 °C, 100 kg/s, 85 % dry turbine efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

DiPippo, Geothermal Power Plants: Principles, Applications, Case Studies and Environmental Impact, 4th ed. (Butterworth-Heinemann, 2016), ch. 5

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.