Off-Grid Solar: PV Array, Battery Bank and Charge Controller

PV array, module count, battery capacity for days of autonomy and charge controller current for an off-grid system from daily energy and sun hours.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 5 kWh/day, 48 V, 4.5 h, 2 daysTelemetry 600 Wh/day, 24 V, 3 days

Results

For a PWM controller size on the array short-circuit current instead: 1.25 × parallel strings × I_sc; with all 2 modules in parallel that is 25 A (divide by the modules per series string).

Controller current estimated as 1.25 × array power/battery voltage (MPPT output side). Size for the worst month; add margin for module temperature derating in hot climates.

PV array power0.21429kW
Modules (rounded up)2.0000
Battery capacity at system voltage (Ah)133.93
Charge controller output current (MPPT: 1.25 × array power / battery voltage)20.833A

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 5 kWh/day, 48 V, 4.5 h, 2 days. The inputs, in the units selected above:

InputValue
Daily energy use (Wh)5,000.0 -
Peak sun hours (design month)4.5000 -
System efficiency (wiring, controller, inverter)75.000 %
Battery system voltage48.000 V
Days of autonomy2.0000 -
Usable depth of discharge50.000 %
Module short-circuit current13.500 A
Module rating540.00 W

Applying the formula below gives:

ResultValue
PV array power1.4815 kW
Modules (rounded up)3.0000
Battery capacity at system voltage (Ah)555.56
Charge controller output current (MPPT: 1.25 × array power / battery voltage)42.188 A

Open this example in the calculator and change any input.

Formula

\(P_{PV} = \frac{E_d}{PSH\cdot\eta_s}, \quad C = \frac{E_dn}{V_{sys}DoD\,\eta_s}, \quad I_{cc} = \frac{1.25\,n_{mod}P_{mod}}{V_{sys}}\ (\text{MPPT}), \quad I_{PWM} = 1.25\,n_p I_{sc,mod}\)

Variables

Symbol Meaning SI unit
\(E_d\) Daily energy use (Wh) -
\(PSH\) Peak sun hours (design month) -
\(\eta_s\) System efficiency (wiring, controller, inverter) -
\(V_{sys}\) Battery system voltage V
\(n\) Days of autonomy -
\(DoD\) Usable depth of discharge -
\(I_{sc,mod}\) Module short-circuit current A
\(P_{mod}\) Module rating W
\(P_{PV}\) PV array power W
\(n_{mod}\) Modules (rounded up) -
\(C\) Battery capacity at system voltage (Ah) -
\(I_{cc}\) Charge controller output current (MPPT: 1.25 × array power / battery voltage) A
\(I_{PWM}\), \(n_p\) PWM controller current (given in a note) and number of parallel strings A, -

Method and standards

Energy balance.

Where it is used

  • Remote instrumentation and telemetry.
  • Off-grid buildings and pumps.

Common mistakes

  • Using annual average sun hours.
  • Ignoring battery efficiency.

Assumptions and limits

  • Daily balance in the design month.
  • The battery capacity divides by the whole system efficiency, which also includes PV-side losses not in the discharge path: slightly conservative. Module temperature derating is not included.
  • The output current is for an MPPT controller; a PWM controller is sized on the array short-circuit current (note).

References

  • Off-grid PV sizing by energy balance (peak sun hours, autonomy, depth of discharge) (definitions)

Questions and answers

What are peak sun hours?

Daily solar energy on the array expressed as hours at 1 kW/m²: 4–6 in most of India, lowest in the monsoon.

Why only 50 % depth of discharge?

Lead-acid batteries last much longer when cycled shallowly; lithium batteries allow 80–90 %.

What do the defaults represent?

A 5 kWh/day load on a 48 V system with 4.5 peak sun hours and two days' autonomy.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.