FireCADCalc

Steel Tape Corrections: Temperature, Pull, Sag and Slope

Corrections to a taped length for temperature, pull, sag and slope, and the corrected horizontal distance.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 30 m tape at 35 °C, 100 N, suspended, 1.5 m rise50 m invar on the ground, cold

Results

Sag correction applies when the tape hangs freely between supports over the whole length (one span). Slope correction uses the exact √(L_c² − h²) form on the length already corrected for temperature, pull and sag. Correction for standardisation (tape's true length) is extra.

Temperature correction-0.50000mm
Pull correction0mm
Sag correction (suspended)0mm
Slope correction-2.5001mm
Corrected horizontal length49.997m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 m tape at 35 °C, 100 N, suspended, 1.5 m rise. The inputs, in the units selected above:

InputValue
Measured length30.000 m
Field temperature35.000 °C
Standard temperature20.000 °C
Expansion coefficient11.600 µm/(m·K)
Applied pull0.10000 kN
Standard pull0.050000 kN
Tape cross-section3.0000 mm²
Tape modulus200.00 GPa
Tape weight per length0.25000 N/m
Height difference between ends1.5000 m

Applying the formula below gives:

ResultValue
Temperature correction5.2200 mm
Pull correction2.5000 mm
Sag correction (suspended)-7.0312 mm
Slope correction-37.523 mm
Corrected horizontal length29.963 m

Open this example in the calculator and change any input.

Formula

\(C_t = \alpha L(T - T_0), \quad C_p = \frac{(P - P_0)L}{AE}, \quad C_s = -\frac{w^2L^3}{24P^2}, \quad L_c = L + C_t + C_p + C_s, \quad C_h = -\left(L_c - \sqrt{L_c^2 - h^2}\right), \quad L_h = L_c + C_h\)

Variables

Symbol Meaning SI unit
\(L\) Measured length m
\(T\) Field temperature K
\(T_0\) Standard temperature K
\(\alpha\) Expansion coefficient 1/K
\(P\) Applied pull N
\(P_0\) Standard pull N
\(A\) Tape cross-section m²
\(E\) Tape modulus Pa
\(w\) Tape weight per length N/m
\(h\) Height difference between ends m
\(C_t\) Temperature correction m
\(C_p\) Pull correction m
\(C_s\) Sag correction (suspended) m
\(C_h\) Slope correction m
\(L_h\) Corrected horizontal length m
\(L_c\) Length after temperature, pull and sag corrections m

Method and standards

Tape corrections.

Where it is used

  • Plant setting-out and baselines.
  • Exam problems.

Common mistakes

  • Applying sag correction to a tape lying on the ground.
  • Wrong sign for temperature.

Assumptions and limits

  • The slope correction is applied to the length already corrected for temperature, pull and sag (L_c), in the exact form; h must be less than L_c.

  • Single-span suspension; uniform tape.

References

  • Standard tape corrections (Punmia, Surveying, vol. 1–2 (Laxmi), vol. 1, ch. 3)

Questions and answers

Which correction is largest?

Usually sag for suspended tapes and slope on steep ground; temperature matters on hot days with long lines.

What is normal tension?

The pull at which the pull correction cancels the sag correction.

What do the defaults represent?

A 30 m steel tape used at 35 °C with 100 N pull, suspended, with 1.5 m height difference.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.