FireCADCalc

Mixing Two Streams: Concentration and Temperature

Flow, concentration and temperature of the mixture of two liquid streams by mass and heat balance, and the flow of the second stream for a target concentration.

Process steam and utilitiesChemical and fertiliserPulp and paperFood, dairy and textileTank and drum

Inputs

Examples: 30 % solution 1 t/h at 60 °C diluted with 2 t/h water at 25 °C; target 12 %Brine 5 % and 20 % streams, 3 and 1 t/hReturn condensate 8 t/h at 90 °C with make-up 2 t/h at 30 °C

Results

Heat of mixing or dilution is not included: diluting strong acids and caustic releases heat and the mixture runs hotter.

Mixture flow4,000.0kg/h
Mixture concentration8.7500%
Mixture temperature (no heat of mixing)32.258°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 % solution 1 t/h at 60 °C diluted with 2 t/h water at 25 °C; target 12 %. The inputs, in the units selected above:

InputValue
Flow of stream 11,000.0 kg/h
Concentration of stream 1 (mass fraction)30.000 %
Temperature of stream 160.000 °C
Specific heat of stream 13.5000 kJ/(kg·K)
Flow of stream 22,000.0 kg/h
Concentration of stream 2 (mass fraction)0 %
Temperature of stream 225.000 °C
Specific heat of stream 24.1800 kJ/(kg·K)
Target concentration for the stream 2 flow output (0 = none)12.000 %

Applying the formula below gives:

ResultValue
Mixture flow3,000.0 kg/h
Mixture concentration10.0000 %
Mixture temperature (no heat of mixing)35.329 °C
Stream 2 flow for the target concentration1,500.0 kg/h

Open this example in the calculator and change any input.

Formula

\(\dot m_3 = \dot m_1 + \dot m_2, \quad x_3 = \frac{\dot m_1 x_1 + \dot m_2 x_2}{\dot m_3}\)

\(T_3 = \frac{\dot m_1 c_1 T_1 + \dot m_2 c_2 T_2}{\dot m_1 c_1 + \dot m_2 c_2}\)

\(\dot m_{2,t} = \dot m_1 \frac{x_1 - x_t}{x_t - x_2}\)

Variables

Symbol Meaning SI unit
\(\dot m_1\) flow of stream 1 kg/s
\(x_1\) concentration of stream 1 -
\(T_1\) temperature of stream 1 K
\(c_1\) specific heat of stream 1 J/(kg·K)
\(\dot m_2\) flow of stream 2 kg/s
\(x_2\) concentration of stream 2 -
\(T_2\) temperature of stream 2 K
\(c_2\) specific heat of stream 2 J/(kg·K)
\(x_t\) target concentration -
\(\dot m_3\) mixture flow kg/s
\(x_3\) mixture concentration -
\(T_3\) mixture temperature K
\(\dot m_{2,t}\) stream 2 flow for the target kg/s

Method and standards

Steady mass balances on total flow and on the solute give the mixture concentration; an energy balance with constant specific heats gives the temperature.

Where it is used

  • Blending chemicals and diluting stock solutions.
  • Mixing condensate return and make-up water.
  • Planning effluent blending.

Common mistakes

  • Mixing volume and mass flows.
  • Ignoring heat of mixing for acids and caustic.
  • Using volume fractions as mass fractions.

Assumptions and limits

  • Steady state; no reaction; no heat of mixing.
  • A target concentration of 0 means "no target"; the stream 2 flow output appears only when a target is entered (the FAQ case uses 12 %).

References

  • Mass and energy balance

Questions and answers

What do 1 t/h of 30 % solution at 60 °C and 2 t/h of water at 25 °C give?

3 t/h at 10 % and about 35 °C; reaching 12 % instead needs 1.5 t/h of water.

Does the method include heat of dilution?

No. Diluting strong acids and caustic releases heat; the real mixture runs hotter.

Can I mix two solutions of the same chemical?

Yes; enter both concentrations. For different chemicals, the concentration is of the one you track.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.