FireCADCalc

Mixer and Splitter Mass Balance

Combined flow and composition of up to three streams mixed together, and the two outlet streams when the mixture is split in a chosen ratio.

Refinery and petrochemicalChemical and fertiliserFood, dairy and textile

Inputs

Examples: Two streams split 70/30Three streams to one outlet

Stream 1

Stream 2

Stream 3

Results

A splitter divides flow only; both outlets have the mixed composition.

Mixed flow1,500.0kg/h
Mixed composition30.000%
Component flow450.00kg/h
Outlet A1,050.0kg/h
Outlet B450.00kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Two streams split 70/30. The inputs, in the units selected above:

InputValue
Stream 1: mass flow1,000.0 kg/h
Stream 1: component mass fraction40.000 %
Stream 2: mass flow500.00 kg/h
Stream 2: component mass fraction10.000 %
Stream 3: mass flow0 kg/h
Stream 3: component mass fraction0 %
Share sent to outlet A70.000 %

Applying the formula below gives:

ResultValue
Mixed flow1,500.0 kg/h
Mixed composition30.000 %
Component flow450.00 kg/h
Outlet A1,050.0 kg/h
Outlet B450.00 kg/h

Open this example in the calculator and change any input.

Formula

\(\dot m = \sum \dot m_i, \quad x = \frac{\sum \dot m_i x_i}{\dot m}, \quad \dot m_A = s\dot m\)

Variables

Symbol Meaning SI unit
\(\dot m_{1}\) Stream 1: mass flow kg/s
\(x_{1}\) Stream 1: component mass fraction -
\(\dot m_{2}\) Stream 2: mass flow kg/s
\(x_{2}\) Stream 2: component mass fraction -
\(\dot m_{3}\) Stream 3: mass flow kg/s
\(x_{3}\) Stream 3: component mass fraction -
\(s\) Share sent to outlet A -
\(\dot m\) Mixed flow kg/s
\(x\) Mixed composition -
\(\dot m_c\) Component flow kg/s
\(\dot m_A\) Outlet A kg/s
\(\dot m_B\) Outlet B kg/s

Method and standards

Mass balances.

Where it is used

  • Blending tanks and headers.
  • Process flow sheets.

Common mistakes

  • Averaging fractions without weighting by flow.
  • Volume for mass.

Assumptions and limits

  • Steady state.

References

  • Total and component mass balances

Questions and answers

1000 kg/h at 40 % with 500 kg/h at 10 %?

1500 kg/h at 30 %; split 70/30 gives 1050 and 450 kg/h.

Different components?

Run the balance for each component.

Energy too?

Use the two-stream mixing calculator for temperature.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.