FireCADCalc

Recycle and Purge Balance with an Inert

Reactor feed, recycle and purge flows and overall conversion for a reactor with single-pass conversion, full product separation and a purge to remove inerts.

Refinery and petrochemicalChemical and fertiliserFood, dairy and textile

Inputs

Examples: 1 % inert, 25 % per pass, 5 % purgeAmmonia-loop style

Results

Total reactor feed (reactant plus inert) R_F + I_F = 364.3 kmol/h.

Product fully removed in the separator; unreacted reactant and inert recycled; purge taken from the recycle gas.

Reactant in the reactor feed344.35kmol/h
Inert in the reactor feed20.000kmol/h
Recycle flow264.35kmol/h
Purge flow13.913kmol/h
Overall conversion86.957%
Inert fraction in the recycle7.1875%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 % inert, 25 % per pass, 5 % purge. The inputs, in the units selected above:

InputValue
Fresh feed (reactant plus inert)100.00 kmol/h
Inert mole fraction in the fresh feed1.0000 %
Single-pass conversion25.000 %
Purge share of the separator gas5.0000 %

Applying the formula below gives:

ResultValue
Reactant in the reactor feed344.35 kmol/h
Inert in the reactor feed20.000 kmol/h
Recycle flow264.35 kmol/h
Purge flow13.913 kmol/h
Overall conversion86.957 %
Inert fraction in the recycle7.1875 %

Open this example in the calculator and change any input.

Formula

\(R_F = \frac{F_0(1 - x_{I0})}{1 - (1 - p)(1 - X)}, \quad I_F = \frac{F_0 x_{I0}}{p}, \quad X_o = 1 - \frac{p R_F(1 - X)}{F_0(1 - x_{I0})}\)

Variables

Symbol Meaning SI unit
\(F_0\) Fresh feed (reactant plus inert) mol/s
\(x_{I0}\) Inert mole fraction in the fresh feed -
\(X\) Single-pass conversion -
\(p\) Purge share of the separator gas -
\(R_F\) Reactant in the reactor feed mol/s
\(I_F\) Inert in the reactor feed mol/s
\(\dot R\) Recycle flow mol/s
\(\dot P\) Purge flow mol/s
\(X_o\) Overall conversion -
\(y_I\) Inert fraction in the recycle -

Method and standards

Loop balances.

Where it is used

  • Ammonia, methanol and hydrogen loops.
  • Examinations.

Common mistakes

  • Purge taken before the separator.
  • Ignoring inerts dissolved in product.

Assumptions and limits

  • Complete product separation, steady state.
  • R_F is the reactant only; the total reactor feed R_F + I_F is given in the note.

References

  • Steady-state balances on reactant and inert around reactor
  • separator and purge (Felder and Rousseau)

Questions and answers

1 % inert, 25 % per pass, 5 % purge?

Reactor feed about 364 kmol/h for 100 fresh (reactant R_F 344 plus inert I_F 20); inert 7 % of the recycle.

Why purge?

Inerts would build up forever in a closed loop.

Trade-off?

More purge loses reactant; less purge raises inert and lowers reaction rate.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.