Worked example
Example: 1 % inert, 25 % per pass, 5 % purge. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fresh feed (reactant plus inert) | 100.00 kmol/h |
| Inert mole fraction in the fresh feed | 1.0000 % |
| Single-pass conversion | 25.000 % |
| Purge share of the separator gas | 5.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reactant in the reactor feed | 344.35 kmol/h |
| Inert in the reactor feed | 20.000 kmol/h |
| Recycle flow | 264.35 kmol/h |
| Purge flow | 13.913 kmol/h |
| Overall conversion | 86.957 % |
| Inert fraction in the recycle | 7.1875 % |
Open this example in the calculator and change any input.
Formula
\(R_F = \frac{F_0(1 - x_{I0})}{1 - (1 - p)(1 - X)}, \quad I_F = \frac{F_0 x_{I0}}{p}, \quad X_o = 1 - \frac{p R_F(1 - X)}{F_0(1 - x_{I0})}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(F_0\) | Fresh feed (reactant plus inert) | mol/s |
| \(x_{I0}\) | Inert mole fraction in the fresh feed | - |
| \(X\) | Single-pass conversion | - |
| \(p\) | Purge share of the separator gas | - |
| \(R_F\) | Reactant in the reactor feed | mol/s |
| \(I_F\) | Inert in the reactor feed | mol/s |
| \(\dot R\) | Recycle flow | mol/s |
| \(\dot P\) | Purge flow | mol/s |
| \(X_o\) | Overall conversion | - |
| \(y_I\) | Inert fraction in the recycle | - |
Method and standards
Loop balances.
Where it is used
- Ammonia, methanol and hydrogen loops.
- Examinations.
Common mistakes
- Purge taken before the separator.
- Ignoring inerts dissolved in product.
Assumptions and limits
- Complete product separation, steady state.
- R_F is the reactant only; the total reactor feed R_F + I_F is given in the note.
References
- Steady-state balances on reactant and inert around reactor
- separator and purge (Felder and Rousseau)
Questions and answers
1 % inert, 25 % per pass, 5 % purge?
Reactor feed about 364 kmol/h for 100 fresh (reactant R_F 344 plus inert I_F 20); inert 7 % of the recycle.
Why purge?
Inerts would build up forever in a closed loop.
Trade-off?
More purge loses reactant; less purge raises inert and lowers reaction rate.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.