Worked example
Example: 30 % solution 1 t/h at 60 °C diluted with 2 t/h water at 25 °C; target 12 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flow of stream 1 | 1,000.0 kg/h |
| Concentration of stream 1 (mass fraction) | 30.000 % |
| Temperature of stream 1 | 60.000 °C |
| Specific heat of stream 1 | 3.5000 kJ/(kg·K) |
| Flow of stream 2 | 2,000.0 kg/h |
| Concentration of stream 2 (mass fraction) | 0 % |
| Temperature of stream 2 | 25.000 °C |
| Specific heat of stream 2 | 4.1800 kJ/(kg·K) |
| Target concentration for the stream 2 flow output (0 = none) | 12.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mixture flow | 3,000.0 kg/h |
| Mixture concentration | 10.0000 % |
| Mixture temperature (no heat of mixing) | 35.329 °C |
| Stream 2 flow for the target concentration | 1,500.0 kg/h |
Open this example in the calculator and change any input.
Formula
\(\dot m_3 = \dot m_1 + \dot m_2, \quad x_3 = \frac{\dot m_1 x_1 + \dot m_2 x_2}{\dot m_3}\)
\(T_3 = \frac{\dot m_1 c_1 T_1 + \dot m_2 c_2 T_2}{\dot m_1 c_1 + \dot m_2 c_2}\)
\(\dot m_{2,t} = \dot m_1 \frac{x_1 - x_t}{x_t - x_2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_1\) | flow of stream 1 | kg/s |
| \(x_1\) | concentration of stream 1 | - |
| \(T_1\) | temperature of stream 1 | K |
| \(c_1\) | specific heat of stream 1 | J/(kg·K) |
| \(\dot m_2\) | flow of stream 2 | kg/s |
| \(x_2\) | concentration of stream 2 | - |
| \(T_2\) | temperature of stream 2 | K |
| \(c_2\) | specific heat of stream 2 | J/(kg·K) |
| \(x_t\) | target concentration | - |
| \(\dot m_3\) | mixture flow | kg/s |
| \(x_3\) | mixture concentration | - |
| \(T_3\) | mixture temperature | K |
| \(\dot m_{2,t}\) | stream 2 flow for the target | kg/s |
Method and standards
Steady mass balances on total flow and on the solute give the mixture concentration; an energy balance with constant specific heats gives the temperature.
Where it is used
- Blending chemicals and diluting stock solutions.
- Mixing condensate return and make-up water.
- Planning effluent blending.
Common mistakes
- Mixing volume and mass flows.
- Ignoring heat of mixing for acids and caustic.
- Using volume fractions as mass fractions.
Assumptions and limits
- Steady state; no reaction; no heat of mixing.
- A target concentration of 0 means "no target"; the stream 2 flow output appears only when a target is entered (the FAQ case uses 12 %).
References
- Mass and energy balance
Questions and answers
What do 1 t/h of 30 % solution at 60 °C and 2 t/h of water at 25 °C give?
3 t/h at 10 % and about 35 °C; reaching 12 % instead needs 1.5 t/h of water.
Does the method include heat of dilution?
No. Diluting strong acids and caustic releases heat; the real mixture runs hotter.
Can I mix two solutions of the same chemical?
Yes; enter both concentrations. For different chemicals, the concentration is of the one you track.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.