FireCADCalc

Medium Sterilisation: Del Factor, Holding Time and Holding-Tube Length

Del factor for a target contamination risk, spore death rate by an Arrhenius law, holding time at temperature and continuous holding-tube length.

Sugar mill and cogenerationDistillery and ethanolChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 40 m3 at 1e9 spores/L, 140 °C continuousBatch hold at 121 °C

Results

Holding phase only: in a batch, heating and cooling contribute part of the Del factor. Axial dispersion in a real holding tube needs a longer tube than plug flow, and in laminar flow the fastest fluid moves at about twice the mean velocity. Defaults are Deindoerfer–Humphrey constants for Bacillus stearothermophilus spores.

Del factor ln(N₀/N)32.236
Specific death rate at T2.98111/min
Holding time10.814min
Holding-tube length (plug flow at the mean velocity)324.41m
Decimal reduction time at T0.77240min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 m3 at 1e9 spores/L, 140 °C continuous. The inputs, in the units selected above:

InputValue
Spores per litre of raw medium1.0000e+09 -
Medium volume per batch40.000 m³
Acceptable surviving spores per batch (e.g. 0.001)0.001000 -
log₁₀ of the Arrhenius constant A (1/s)36.200 -
Activation energy for spore death283.00 kJ/mol
Holding temperature140.00 °C
Velocity in the holding tube0.50000 m/s

Applying the formula below gives:

ResultValue
Del factor ln(N₀/N)38.228
Specific death rate at T158.16 1/min
Holding time0.24170 min
Holding-tube length (plug flow at the mean velocity)7.2510 m
Decimal reduction time at T0.014558 min

Open this example in the calculator and change any input.

Formula

\(N_0 = n_0 V \times 1000\ \mathrm{L/m^3}, \quad \nabla = \ln\frac{N_0}{N}, \quad k_d = Ae^{-E_d/RT}, \quad t_h = \frac{\nabla}{k_d}, \quad L = ut_h, \quad D_T = \frac{\ln10}{k_d}\)

Variables

Symbol Meaning SI unit
\(n_0\) Spores per litre of raw medium -
\(V\) Medium volume per batch m³
\(N\) Acceptable surviving spores per batch (e.g. 0.001) -
\(\log_{10}A\) log₁₀ of the Arrhenius constant A (1/s) -
\(E_d\) Activation energy for spore death J/mol
\(T\) Holding temperature K
\(u\) Velocity in the holding tube m/s
\(\nabla\) Del factor ln(N₀/N) -
\(k_d\) Specific death rate at T 1/s
\(t_h\) Holding time s
\(L\) Holding-tube length (plug flow at the mean velocity) m
\(D_T\) Decimal reduction time at T s
\(N_0\) Spores in the batch before sterilisation -

Method and standards

Del factor with Arrhenius death kinetics.

Where it is used

  • Fermenter medium and molasses sterilisation.
  • Continuous sterilisers for distilleries and pharma.

Common mistakes

  • Ignoring heating and cooling in a batch.
  • Using food D-values for a different organism.

Assumptions and limits

  • First-order death; plug flow in the tube at the mean velocity. Real tubes need a margin for axial dispersion, and laminar flow (fastest fluid at about twice the mean velocity) needs a longer tube.
  • N₀ is the total spores in the batch: n₀ per litre times the volume in litres.

References

  • Doran
  • Bioprocess Engineering Principles
  • 2nd ed. (Academic Press, 2013)
  • ch. 14 (sterilisation: Del factor, Arrhenius death kinetics; Deindoerfer and Humphrey constants for B. stearothermophilus)

Questions and answers

What is the Del factor?

The natural log of the reduction in spore numbers the sterilisation must achieve: ln(spores in / spores allowed to survive).

Why a target like 0.001?

It means one batch in a thousand may carry a surviving spore; the design target is a risk, not zero.

Why continuous sterilisation?

At 140 °C the holding time is seconds instead of minutes, which damages the medium less.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.