Worked example
Example: 40 m3 at 1e9 spores/L, 140 °C continuous. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Spores per litre of raw medium | 1.0000e+09 - |
| Medium volume per batch | 40.000 m³ |
| Acceptable surviving spores per batch (e.g. 0.001) | 0.001000 - |
| log₁₀ of the Arrhenius constant A (1/s) | 36.200 - |
| Activation energy for spore death | 283.00 kJ/mol |
| Holding temperature | 140.00 °C |
| Velocity in the holding tube | 0.50000 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Del factor ln(N₀/N) | 38.228 |
| Specific death rate at T | 158.16 1/min |
| Holding time | 0.24170 min |
| Holding-tube length (plug flow at the mean velocity) | 7.2510 m |
| Decimal reduction time at T | 0.014558 min |
Open this example in the calculator and change any input.
Formula
\(N_0 = n_0 V \times 1000\ \mathrm{L/m^3}, \quad \nabla = \ln\frac{N_0}{N}, \quad k_d = Ae^{-E_d/RT}, \quad t_h = \frac{\nabla}{k_d}, \quad L = ut_h, \quad D_T = \frac{\ln10}{k_d}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(n_0\) | Spores per litre of raw medium | - |
| \(V\) | Medium volume per batch | m³ |
| \(N\) | Acceptable surviving spores per batch (e.g. 0.001) | - |
| \(\log_{10}A\) | log₁₀ of the Arrhenius constant A (1/s) | - |
| \(E_d\) | Activation energy for spore death | J/mol |
| \(T\) | Holding temperature | K |
| \(u\) | Velocity in the holding tube | m/s |
| \(\nabla\) | Del factor ln(N₀/N) | - |
| \(k_d\) | Specific death rate at T | 1/s |
| \(t_h\) | Holding time | s |
| \(L\) | Holding-tube length (plug flow at the mean velocity) | m |
| \(D_T\) | Decimal reduction time at T | s |
| \(N_0\) | Spores in the batch before sterilisation | - |
Method and standards
Del factor with Arrhenius death kinetics.
Where it is used
- Fermenter medium and molasses sterilisation.
- Continuous sterilisers for distilleries and pharma.
Common mistakes
- Ignoring heating and cooling in a batch.
- Using food D-values for a different organism.
Assumptions and limits
- First-order death; plug flow in the tube at the mean velocity. Real tubes need a margin for axial dispersion, and laminar flow (fastest fluid at about twice the mean velocity) needs a longer tube.
- N₀ is the total spores in the batch: n₀ per litre times the volume in litres.
References
- Doran
- Bioprocess Engineering Principles
- 2nd ed. (Academic Press, 2013)
- ch. 14 (sterilisation: Del factor, Arrhenius death kinetics; Deindoerfer and Humphrey constants for B. stearothermophilus)
Questions and answers
What is the Del factor?
The natural log of the reduction in spore numbers the sterilisation must achieve: ln(spores in / spores allowed to survive).
Why a target like 0.001?
It means one batch in a thousand may carry a surviving spore; the design target is a risk, not zero.
Why continuous sterilisation?
At 140 °C the holding time is seconds instead of minutes, which damages the medium less.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.