FireCADCalc

Oxygen Uptake Rate and Aeration Needed for a Fermenter

Oxygen uptake rate of a culture from biomass and specific uptake, the kLa needed above a critical dissolved oxygen, and the air flow (vvm) required.

Sugar mill and cogenerationDistillery and ethanolChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 30 g/L at 8 mmol/(g h), 50 m3Yeast propagation 10 g/L

Results

High-density aerobic cultures often need kLa of several hundred per hour; above that, oxygen-enriched air or pressure is used.

Oxygen uptake rate0.95994kg/(m³·h)
Oxygen demand of the broth19.199kg/h
kLa needed147.681/h
Air flow at 0 °C, 1 atm427.95Nm³/h
Air flow per broth volume per minute (air at 0 °C, 1 atm)0.35663

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 g/L at 8 mmol/(g h), 50 m3. The inputs, in the units selected above:

InputValue
Biomass concentration (dry cell weight)30.000 g/L
Specific oxygen uptake (mmol O₂ per g dry cells per hour)8.0000 -
Broth volume50.000 m³
Saturation dissolved oxygen7.2000 mg/L
Dissolved oxygen to hold (above critical)1.5000 mg/L
Oxygen absorbed from the air20.000 %

Applying the formula below gives:

ResultValue
Oxygen uptake rate7.6795 kg/(m³·h)
Oxygen demand of the broth383.98 kg/h
kLa needed1,347.3 1/h
Air flow at 0 °C, 1 atm6,419.3 Nm³/h
Air flow per broth volume per minute (air at 0 °C, 1 atm)2.1398

Open this example in the calculator and change any input.

Formula

\(OUR = q_{O_2}X, \quad k_La_{req} = \frac{OUR}{C^* - C_{crit}}, \quad Q_{air} = \frac{OUR\cdot V}{0.2095\,\eta_{O_2}}\cdot22.414\ \mathrm{L/mol}\)

Variables

Symbol Meaning SI unit
\(X\) Biomass concentration (dry cell weight) kg/m³
\(q_{O_2}\) Specific oxygen uptake (mmol O₂ per g dry cells per hour) -
\(V\) Broth volume m³
\(C^*\) Saturation dissolved oxygen kg/m³
\(C_{crit}\) Dissolved oxygen to hold (above critical) kg/m³
\(\eta_{O_2}\) Oxygen absorbed from the air -
\(OUR\) Oxygen uptake rate kg/(m³·s)
\(\dot m_{O_2}\) Oxygen demand of the broth kg/s
\(k_La_{req}\) kLa needed 1/s
\(Q_{air}\) Air flow at 0 °C, 1 atm Nm³/s
\(vvm\) Air flow per broth volume per minute (air at 0 °C, 1 atm) -

Method and standards

Oxygen balance.

Where it is used

  • Fermenter blower and sparger sizing.
  • Yeast propagation aeration.

Common mistakes

  • Mixing mmol and mg units.
  • Assuming full oxygen absorption.

Assumptions and limits

  • Steady state; ideal gas at 0 °C, 1 atm.
  • vvm is on normal air (0 °C, 1 atm); vvm quoted at inlet or actual conditions is larger by the temperature and pressure ratio.
  • X is dry cell weight and q_O₂ is per gram of dry cells; q_O₂ is entered as a plain number in mmol/(g·h).

References

  • Doran
  • Bioprocess Engineering Principles
  • 2nd ed. (Academic Press, 2013)
  • ch. 10 (oxygen demand and transfer)

Questions and answers

What is vvm?

Volume of air per volume of broth per minute; 0.5–1.5 is common in aerobic fermenters.

Why keep DO above a critical value?

Below it the cells' oxygen uptake falls and growth or product formation slows; for yeast and most bacteria it is about 5–10 % of air saturation.

What do the defaults give?

30 g/L at 8 mmol/(g·h): OUR 7.7 kg/(m³·h) (240 mmol/(L·h)), kLa needed about 1,350 /h: higher than air alone usually gives.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.