FireCADCalc

kLa by the Dynamic Gassing-Out Method, with a van 't Riet Estimate

Oxygen transfer coefficient kLa from two dissolved-oxygen readings during re-aeration, and van 't Riet's estimate from power per volume and gas velocity.

Sugar mill and cogenerationDistillery and ethanolChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 2 to 6 mg/L in 40 s, coalescingBroth, 1 to 4 mg/L in 25 s, non-coalescing

Results

Correct for probe response time when 1/kLa is less than about five times the probe's time constant. Van 't Riet's correlations hold within about 20–40 % for vessels up to 2.6 m³.

kLa from the readings99.8131/h
kLa by van 't Riet673.381/h
Maximum oxygen transfer rate at C = 00.69869kg/(m³·h)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 to 6 mg/L in 40 s, coalescing. The inputs, in the units selected above:

InputValue
Saturation dissolved oxygen7.5000 mg/L
Dissolved oxygen at t₁2.0000 mg/L
Dissolved oxygen at t₂6.0000 mg/L
Time between the readings40.000 s
Gassed power per volume1.0000 kW/m³
Superficial gas velocity0.010000 m/s
Liquid typeCoalescing (pure water, simple media)

Applying the formula below gives:

ResultValue
kLa from the readings116.94 1/h
kLa by van 't Riet148.35 1/h
Maximum oxygen transfer rate at C = 00.87702 kg/(m³·h)

Open this example in the calculator and change any input.

Formula

\(\ln\frac{C^* - C_1}{C^* - C_2} = k_La(t_2 - t_1)\)

\(k_La = 0.026\left(\frac{P}{V}\right)^{0.4}v_s^{0.5}\ \text{(coalescing)}, \quad 0.002\left(\frac{P}{V}\right)^{0.7}v_s^{0.2}\ \text{(non-coalescing)}\ \ (\mathrm{SI})\)

Variables

Symbol Meaning SI unit
\(C^*\) Saturation dissolved oxygen kg/m³
\(C_1\) Dissolved oxygen at t₁ kg/m³
\(C_2\) Dissolved oxygen at t₂ kg/m³
\(t_2 - t_1\) Time between the readings s
\(P/V\) Gassed power per volume W/m³
\(v_s\) Superficial gas velocity m/s
\(\text{liquid}\) Liquid type -
\(k_La\) kLa from the readings 1/s
\(k_La_{vR}\) kLa by van 't Riet 1/s
\(OTR_{max}\) Maximum oxygen transfer rate at C = 0 kg/(m³·s)

Method and standards

Dynamic method; van 't Riet correlations.

Where it is used

  • Fermenter and aeration tank testing.
  • Scale-up checks.

Common mistakes

  • Ignoring probe lag.
  • Using readings near saturation.

Assumptions and limits

  • Well-mixed liquid; constant C*.
  • The two-point form holds when the liquid takes up no oxygen during re-aeration (water or broth without respiring cells). With a respiring culture the balance is dC/dt = kLa(C* − C) − OUR, and the oxygen uptake rate must be included.
  • Van 't Riet's correlations come from vessels up to 2.6 m³ over their own ranges of power input and gas velocity; at larger scale or far outside those conditions treat the estimate as indicative only.

References

  • Doran
  • Bioprocess Engineering Principles
  • 2nd ed. (Academic Press, 2013)
  • ch. 10 (oxygen transfer, dynamic method)
  • van 't Riet (1979)
  • Ind. Eng. Chem. Process Des. Dev. 18: 357

Questions and answers

How is the test done?

Strip the oxygen with nitrogen (or stop the air), then restart aeration and log the dissolved-oxygen rise; ln(C* − C) falls linearly with time at slope −kLa.

Why does the liquid type matter?

Salts and broth components stop bubbles coalescing, giving smaller bubbles and higher kLa at the same power.

What do the defaults give?

DO rising from 2 to 6 mg/L in 40 s at C* 7.5 mg/L: kLa about 117 /h; van 't Riet gives about 150 /h at 1 kW/m³ and 1 cm/s.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.