FireCADCalc

Brake Temperature Build-up over Repeated Stops

Brake disc temperature after a series of repeated stops with Newtonian cooling between them, and the limiting temperature for endless cycling, for fade checks.

Inputs

Examples: Illustrative ten stops from 100 km/h every 60 sFade test 15 stops every 45 sVan downhill stops

Accepted: 50 to 100,000 kg
Accepted: 3.6 to 288 km/h
Accepted: 30 to 100 %
Accepted: 1 to 4
Accepted: 1 to 100 kg
Accepted: 0.3 to 1 kJ/(kg·K)
Accepted: 5 to 500 W/(m²·K)
Accepted: 0.01 to 2 m²
Accepted: 5 to 3,600 s
Accepted: 1 to 100
Accepted: -43.15 to 56.85 °C

Results

Each stop adds ΔT = share of ½mv²/(m_dc); between stops the disc cools as e^(−t/τ), τ = m_dc/(hA). The temperatures form a geometric series. Cooling coefficients rise with speed and vented discs; use a measured τ when available.

Temperature rise per stop72.000K
Disc temperature just after the last stop574.03°C
Limiting temperature after many stops696.60°C
Cooling time constant6.6138min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative ten stops from 100 km/h every 60 s. The inputs, in the units selected above:

InputValue
Vehicle mass1,600.0 kg
Speed at brake application100.00 km/h
Front axle share of braking70.000 %
Discs on the front axle2.0000 -
Disc mass8.0000 kg
Disc specific heat0.50000 kJ/(kg·K)
Mean cooling coefficient60.000 W/(m²·K)
Disc cooling area0.15000 m²
Time between stops60.000 s
Number of stops10.000 -
Ambient temperature25.000 °C

Applying the formula below gives:

ResultValue
Temperature rise per stop54.012 K
Disc temperature just after the last stop341.83 °C
Limiting temperature after many stops452.71 °C
Cooling time constant7.4074 min

Open this example in the calculator and change any input.

Formula

\(\Delta T_1 = \frac{\phi\,\tfrac12mv^2}{n_dm_dc}, \quad T_n = T_a + \Delta T_1\frac{1 - e^{-nt_c/\tau}}{1 - e^{-t_c/\tau}}, \quad \tau = \frac{m_dc}{hA_d}\)

Variables

Symbol Meaning SI unit
\(m\) Vehicle mass kg
\(v\) Speed at brake application m/s
\(\phi\) Front axle share of braking -
\(n_d\) Discs on the front axle -
\(m_d\) Disc mass kg
\(c\) Disc specific heat J/(kg·K)
\(h\) Mean cooling coefficient W/(m²·K)
\(A_d\) Disc cooling area m²
\(t_c\) Time between stops s
\(n\) Number of stops -
\(T_a\) Ambient temperature K
\(\Delta T_1\) Temperature rise per stop K
\(T_n\) Disc temperature just after the last stop K
\(T_\infty\) Limiting temperature after many stops K
\(\tau\) Cooling time constant s

Method and standards

Repeated-stop heating.

Where it is used

  • Brake sizing and fade tests.
  • Mountain descent checks.

Common mistakes

  • Assuming full cooling between stops.
  • Using a single cooling coefficient for all speeds.

Assumptions and limits

  • Lumped disc temperature; constant cooling coefficient.

References

  • Repeated-stop brake temperature (Newtonian cooling)

Questions and answers

Why does temperature keep rising stop after stop?

If the disc does not cool fully between stops, each stop starts hotter, approaching a limit set by the cooling time constant.

What temperatures cause fade?

Ordinary pads begin to fade around 350–450 °C; brake fluid near the caliper may boil if heat soaks back.

What do the defaults represent?

An illustrative 1,600 kg car braking from 100 km/h every 60 s, ten times, with 70 % front braking on two 8 kg discs.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Limpert, Brake Design and Safety, 3rd ed. (SAE, 2011), ch. 3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.