Worked example
Example: Illustrative ten stops from 100 km/h every 60 s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vehicle mass | 1,600.0 kg |
| Speed at brake application | 100.00 km/h |
| Front axle share of braking | 70.000 % |
| Discs on the front axle | 2.0000 - |
| Disc mass | 8.0000 kg |
| Disc specific heat | 0.50000 kJ/(kg·K) |
| Mean cooling coefficient | 60.000 W/(m²·K) |
| Disc cooling area | 0.15000 m² |
| Time between stops | 60.000 s |
| Number of stops | 10.000 - |
| Ambient temperature | 25.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Temperature rise per stop | 54.012 K |
| Disc temperature just after the last stop | 341.83 °C |
| Limiting temperature after many stops | 452.71 °C |
| Cooling time constant | 7.4074 min |
Open this example in the calculator and change any input.
Formula
\(\Delta T_1 = \frac{\phi\,\tfrac12mv^2}{n_dm_dc}, \quad T_n = T_a + \Delta T_1\frac{1 - e^{-nt_c/\tau}}{1 - e^{-t_c/\tau}}, \quad \tau = \frac{m_dc}{hA_d}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m\) | Vehicle mass | kg |
| \(v\) | Speed at brake application | m/s |
| \(\phi\) | Front axle share of braking | - |
| \(n_d\) | Discs on the front axle | - |
| \(m_d\) | Disc mass | kg |
| \(c\) | Disc specific heat | J/(kg·K) |
| \(h\) | Mean cooling coefficient | W/(m²·K) |
| \(A_d\) | Disc cooling area | m² |
| \(t_c\) | Time between stops | s |
| \(n\) | Number of stops | - |
| \(T_a\) | Ambient temperature | K |
| \(\Delta T_1\) | Temperature rise per stop | K |
| \(T_n\) | Disc temperature just after the last stop | K |
| \(T_\infty\) | Limiting temperature after many stops | K |
| \(\tau\) | Cooling time constant | s |
Method and standards
Repeated-stop heating.
Where it is used
- Brake sizing and fade tests.
- Mountain descent checks.
Common mistakes
- Assuming full cooling between stops.
- Using a single cooling coefficient for all speeds.
Assumptions and limits
- Lumped disc temperature; constant cooling coefficient.
References
- Repeated-stop brake temperature (Newtonian cooling)
Questions and answers
Why does temperature keep rising stop after stop?
If the disc does not cool fully between stops, each stop starts hotter, approaching a limit set by the cooling time constant.
What temperatures cause fade?
Ordinary pads begin to fade around 350–450 °C; brake fluid near the caliper may boil if heat soaks back.
What do the defaults represent?
An illustrative 1,600 kg car braking from 100 km/h every 60 s, ten times, with 70 % front braking on two 8 kg discs.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Limpert, Brake Design and Safety, 3rd ed. (SAE, 2011), ch. 3