FireCADCalc

Gearbox Power Loss, Efficiency and Oil Temperature Rise

Output power and losses of a gear train from the number of meshes in the power path, mesh efficiency and no-load churning loss, and the oil temperature rise.

Inputs

Examples: Illustrative 150 kW, two meshesIndustrial 3-stage 500 kWPart load 20 kW, same box

Accepted: 0.1 to 100,000 kW
Accepted: 1 to 10
Accepted: 90 to 100 %
Accepted: 0 to 1,000 kW
Accepted: 0.06 to 6,000 L/min
Accepted: 700 to 1,000 kg/m³
Accepted: 1.5 to 2.6 kJ/(kg·K)

Results

P_out = P_in·η_mⁿ − P₀: load-dependent mesh and bearing losses compound per stage, while churning, windage and seal losses (P₀) are roughly fixed at a speed, so part-load efficiency is poorer. All loss heat goes into the oil: ΔT = P_loss/(V̇ρc_p) through the cooler circuit.

Output power17.904kW
Power loss2.0955kW
Overall efficiency89.523%
Oil temperature rise through the box2.4086K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 150 kW, two meshes. The inputs, in the units selected above:

InputValue
Input power150.00 kW
Gear meshes in the power path2.0000 -
Efficiency per mesh (with bearings)98.500 %
No-load churning and seal loss1.5000 kW
Oil flow through the cooler30.000 L/min
Oil density870.00 kg/m³
Oil specific heat2.0000 kJ/(kg·K)

Applying the formula below gives:

ResultValue
Output power144.03 kW
Power loss5.9662 kW
Overall efficiency96.022 %
Oil temperature rise through the box6.8578 K

Open this example in the calculator and change any input.

Formula

\(P_{out} = P_{in}\eta_m^n - P_0, \quad \Delta T_o = \frac{P_{in} - P_{out}}{\dot V_o\rho_oc_{p,o}}\)

Variables

Symbol Meaning SI unit
\(P_{in}\) Input power W
\(n\) Gear meshes in the power path -
\(\eta_m\) Efficiency per mesh (with bearings) -
\(P_0\) No-load churning and seal loss W
\(\dot V_o\) Oil flow through the cooler m³/s
\(\rho_o\) Oil density kg/m³
\(c_{p,o}\) Oil specific heat J/(kg·K)
\(P_{out}\) Output power W
\(P_{loss}\) Power loss W
\(\eta\) Overall efficiency -
\(\Delta T_o\) Oil temperature rise through the box K

Method and standards

Gearbox losses.

Where it is used

  • Wheel power from engine power.
  • Oil cooler sizing for gear units.

Common mistakes

  • Ignoring no-load losses at part load.
  • Counting an idler mesh twice.

Assumptions and limits

  • Steady state; all losses to oil.

References

  • Stage efficiency and fixed losses

Questions and answers

What mesh efficiency is typical?

About 98–99 % per spur or helical mesh with its bearings; worm gears are far lower.

Why is part-load efficiency worse?

Churning and seal losses stay almost constant while transmitted power falls.

What do the defaults represent?

An illustrative 150 kW two-mesh gearbox at 98.5 % per mesh, 1.5 kW churning loss, cooled by 30 L/min of oil.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Naunheimer, Bertsche, Ryborz and Novak, Automotive Transmissions, 2nd ed. (Springer, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.