Worked example
Example: Horizontal 3 m × 10 m, 2 m level. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Tank orientation | Horizontal (flat ends) |
| Diameter | 3.0000 m |
| Length (horizontal) or height (vertical) | 10.000 m |
| Liquid level | 2.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Wetted area | 67.331 m² |
| Total surface area | 108.38 m² |
| Wetted share | 62.122 % |
| Liquid volume | 50.060 m³ |
Open this example in the calculator and change any input.
Formula
\(\theta = 2\arccos\frac{r - h}{r}, \quad A_w = r\theta L + 2\cdot\frac{r^2}{2}(\theta - \sin\theta)\ \text{(horizontal)}, \quad A_w = \pi r^2 + \pi Dh\ \text{(vertical)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{orientation}\) | Tank orientation | - |
| \(D\) | Diameter | m |
| \(L\) | Length (horizontal) or height (vertical) | m |
| \(h\) | Liquid level | m |
| \(A_w\) | Wetted area | m² |
| \(A_t\) | Total surface area | m² |
| \(A_w/A_t\) | Wetted share | - |
| \(V\) | Liquid volume | m³ |
Method and standards
Segment geometry.
Where it is used
- Tank heating and insulation.
- Fire exposure and coating quantities.
Common mistakes
- Using total area for heat input.
- Ignoring dished heads on long horizontal tanks.
Assumptions and limits
A level above the tank height (vertical) or diameter (horizontal) is taken as full and flagged.
The result is the geometric wetted area. Fire-relief codes count only the wetted area up to a set height above grade (and treat heads in their own way); apply that limit yourself.
Flat ends.
References
- Circular segment geometry (definitions)
Questions and answers
Why wetted area?
Heat flows into a tank mainly through the liquid-wetted wall; it sets heat loss, heating and fire-exposure loads.
How is a horizontal tank's wetted shell found?
From the central angle θ of the liquid surface: wetted shell = rθL.
What do the defaults represent?
A horizontal tank 3 m diameter, 10 m long, 2 m of liquid.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.