FireCADCalc

Aircraft Lift, Drag and Lift-to-Drag Ratio from the Drag Polar

Lift coefficient, induced and total drag, power required and L/D of an aircraft in level flight, with the speed for best L/D, from a parabolic drag polar.

Inputs

Examples: Illustrative light aircraft: 12 kN, 16.2 m2, 60 m/s, 1500 mBusiness jet: 80 kN, 30 m2, 200 m/s, 11000 mSmall UAV: 150 N, 0.9 m2, 20 m/s, 300 m

Accepted: 100 to 10,000,000 N
Accepted: 0.1 to 1,000 m²
Accepted: 3.6 to 1,440 km/h
Accepted: -1,000 to 20,000 m
Accepted: 0.005 to 0.2
Accepted: 1 to 40
Accepted: 0.4 to 1

Results

Parabolic drag polar C_D = C_D0 + C_L²/(πeAR) in steady level flight (L = W). Above about Mach 0.6 compressibility drag adds to C_D0.

Air density (ISA)1.0581kg/m³
Lift coefficient W/(qS)0.38894
Drag coefficient0.035134
Drag (= thrust required)1,084.0N
Lift-to-drag ratio11.070
Power required DV65.039kW
Maximum lift-to-drag ratio13.123
Speed for maximum L/D (minimum drag)160.02km/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative light aircraft: 12 kN, 16.2 m2, 60 m/s, 1500 m. The inputs, in the units selected above:

InputValue
Aircraft weight12,000 N
Wing area16.200 m²
True airspeed216.00 km/h
Altitude (ISA, geopotential)1,500.0 m
Zero-lift drag coefficient0.027000 -
Aspect ratio b²/S7.4000 -
Oswald efficiency factor0.80000 -

Applying the formula below gives:

ResultValue
Air density (ISA)1.0581 kg/m³
Lift coefficient W/(qS)0.38894
Drag coefficient0.035134
Drag (= thrust required)1,084.0 N
Lift-to-drag ratio11.070
Power required DV65.039 kW
Maximum lift-to-drag ratio13.123
Speed for maximum L/D (minimum drag)160.02 km/h

Open this example in the calculator and change any input.

Formula

\(C_L = \frac{W}{\frac{1}{2}\rho V^2 S}, \quad C_D = C_{D0} + \frac{C_L^2}{\pi eAR}, \quad D = \tfrac{1}{2}\rho V^2SC_D\)

\(\left(\frac{L}{D}\right)_{max} = \frac{1}{2\sqrt{kC_{D0}}}, \quad V_{md} = \sqrt{\frac{2W}{\rho S}}\left(\frac{k}{C_{D0}}\right)^{1/4}, \quad k = \frac{1}{\pi eAR}\)

Variables

Symbol Meaning SI unit
\(W\) Aircraft weight N
\(S\) Wing area m²
\(V\) True airspeed m/s
\(h\) Altitude (ISA, geopotential) m
\(C_{D0}\) Zero-lift drag coefficient -
\(AR\) Aspect ratio b²/S -
\(e\) Oswald efficiency factor -
\(\rho\) Air density (ISA) kg/m³
\(C_L\) Lift coefficient W/(qS) -
\(C_D\) Drag coefficient -
\(D\) Drag (= thrust required) N
\(L/D\) Lift-to-drag ratio -
\(P_R\) Power required DV W
\((L/D)_{max}\) Maximum lift-to-drag ratio -
\(V_{md}\) Speed for maximum L/D (minimum drag) m/s

Method and standards

Steady level flight with a parabolic drag polar.

Where it is used

  • Aircraft and UAV performance estimates.
  • Choosing cruise speed and comparing designs.

Common mistakes

  • Using indicated instead of true airspeed.
  • Ignoring compressibility at high subsonic speed.

Assumptions and limits

  • Steady level flight, parabolic polar, ISA.

References

  • Parabolic drag polar with induced drag

Questions and answers

Why is drag lowest at one particular speed?

Parasite drag rises with V² while induced drag falls as 1/V²; they are equal at the minimum-drag speed, which gives the best L/D.

What is the Oswald factor?

It corrects the ideal elliptic-wing induced drag for the real wing and fuselage; typical values are 0.7–0.85.

What do the defaults represent?

An illustrative light aircraft of 12 kN weight and 16.2 m² wing (aspect ratio 7.4) at 60 m/s and 1,500 m altitude.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Anderson, Introduction to Flight, 7th ed. (McGraw-Hill, 2012), sec. 5.14 and 6.3–6.6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.