FireCADCalc

Street Lighting: Average Illuminance and Pole Spacing

Average road illuminance from luminaire flux, utilisation and maintenance factors, road width and pole spacing, and the spacing for a target.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 15,000 lm every 30 m, 8 m roadOpposite 20,000 lm, 14 m road

Results

Lumen method for roads: CU from the luminaire's utilisation curve for the road width and mounting height. Uniformity also limits spacing (often S ≤ 3–4 times mounting height).

Average illuminance20.000lx
Spacing for the target40.000m
Spacing for the target per road width (not S/h: compare S with the mounting height separately)5.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 15,000 lm every 30 m, 8 m road. The inputs, in the units selected above:

InputValue
Luminous flux per luminaire (lm)15,000 -
Coefficient of utilisation40.000 %
Maintenance factor80.000 %
Road width8.0000 m
Pole spacing30.000 m
ArrangementSingle-sided or staggered (one luminaire per spacing)
Target average illuminance15.000 lx

Applying the formula below gives:

ResultValue
Average illuminance20.000 lx
Spacing for the target40.000 m
Spacing for the target per road width (not S/h: compare S with the mounting height separately)5.0000

Open this example in the calculator and change any input.

Formula

\(E_{avg} = \frac{n\Phi\,CU\,MF}{WS}, \quad S_{req} = \frac{n\Phi\,CU\,MF}{WE_t}\)

Variables

Symbol Meaning SI unit
\(\Phi\) Luminous flux per luminaire (lm) -
\(CU\) Coefficient of utilisation -
\(MF\) Maintenance factor -
\(W\) Road width m
\(S\) Pole spacing m
\(\text{arrangement}\) Arrangement -
\(E_t\) Target average illuminance lx
\(E_{avg}\) Average illuminance lx
\(S_{req}\) Spacing for the target m
\(S_{req}/W\) Spacing for the target per road width; this is not the S/h uniformity ratio, so compare S with the mounting height separately -

Method and standards

Lumen method.

Where it is used

  • Plant roads and yards.
  • Retrofit checks.

Common mistakes

  • Ignoring uniformity.
  • Using lamp watts instead of lumens.

Assumptions and limits

  • Average values only.

References

  • Lumen method for road lighting
  • E = ΦCU·MF/(WS) (illuminating engineering practice)

Questions and answers

What is the coefficient of utilisation?

The share of lamp flux that lands on the road strip, from the luminaire's photometric curve.

Why a maintenance factor?

Lamp output falls with age and dirt on the optics; 0.7–0.85 is common for LED road lights.

What do the defaults represent?

15,000 lm LED luminaires every 30 m on one side of an 8 m plant road.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.