FireCADCalc

Rocket Nozzle Exit Mach, Thrust Coefficient and Specific Impulse

Exit Mach number and pressure, thrust coefficient, c*, thrust and specific impulse of an ideal rocket nozzle from chamber conditions and area ratio.

Inputs

Examples: Illustrative kerosene-oxygen: 7 MPa, 3400 K, gamma 1.22, M 22.5, area ratio 16, sea levelVacuum stage: 5 MPa, area ratio 80, vacuumCold-gas nitrogen thruster: 1 MPa, 300 K, gamma 1.4, M 28, ratio 50, vacuum

Accepted: 0.01 to 50 MPa
Accepted: 300 to 4,500 K
Accepted: 1.05 to 1.67
Accepted: 2 to 50 kg/kmol
Accepted: 1.01 to 300
Accepted: 0.001 to 100,000 cm²
Accepted: 0 to 200 kPa

Results

Ideal frozen-composition nozzle: isentropic, one-dimensional, perfect gas. Real nozzles reach about 92–98 % of the ideal C_F.

Exit Mach number5.9138
Exit pressure0.69219kPa
Thrust coefficient1.7292
Characteristic velocity435.89m/s
Thrust0.017292kN
Specific impulse76.858s
Propellant mass flow0.022941kg/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative kerosene-oxygen: 7 MPa, 3400 K, gamma 1.22, M 22.5, area ratio 16, sea level. The inputs, in the units selected above:

InputValue
Chamber pressure7.0000 MPa
Chamber temperature3,400.0 K
Ratio of specific heats of the exhaust1.2200 -
Exhaust molar mass22.500 kg/kmol
Nozzle area ratio A_e/A_t16.000 -
Throat area200.00 cm²
Ambient pressure101.33 kPa

Applying the formula below gives:

ResultValue
Exit Mach number3.6799
Exit pressure44.505 kPa
Thrust coefficient1.5507
Characteristic velocity1,718.1 m/s
Thrust217.10 kN
Specific impulse271.69 s
Propellant mass flow81.483 kg/s

Open this example in the calculator and change any input.

Formula

\(\varepsilon = \frac{1}{M_e}\left[\frac{2}{\gamma + 1}\left(1 + \frac{\gamma - 1}{2}M_e^2\right)\right]^{\frac{\gamma + 1}{2(\gamma - 1)}}, \quad c^* = \frac{\sqrt{\gamma RT_c}}{\gamma\sqrt{\left(\frac{2}{\gamma + 1}\right)^{\frac{\gamma + 1}{\gamma - 1}}}}\)

\(C_F = \sqrt{\frac{2\gamma^2}{\gamma - 1}\left(\frac{2}{\gamma + 1}\right)^{\frac{\gamma + 1}{\gamma - 1}}\left[1 - \left(\frac{p_e}{p_c}\right)^{\frac{\gamma - 1}{\gamma}}\right]} + \frac{p_e - p_a}{p_c}\varepsilon, \quad F = C_Fp_cA_t\)

Variables

Symbol Meaning SI unit
\(p_c\) Chamber pressure Pa
\(T_c\) Chamber temperature K
\(\gamma\) Ratio of specific heats of the exhaust -
\(\mathcal{M}\) Exhaust molar mass kg/kmol
\(\varepsilon\) Nozzle area ratio A_e/A_t -
\(A_t\) Throat area m²
\(p_a\) Ambient pressure Pa
\(M_e\) Exit Mach number -
\(p_e\) Exit pressure Pa
\(C_F\) Thrust coefficient -
\(c^*\) Characteristic velocity m/s
\(F\) Thrust N
\(I_{sp}\) Specific impulse s
\(\dot m\) Propellant mass flow kg/s

Method and standards

Ideal rocket thermodynamics.

Where it is used

  • Rocket engine and motor preliminary design.
  • Comparing sea-level and vacuum nozzles.

Common mistakes

  • Using the sea-level C_F for a vacuum stage.
  • Ignoring flow separation in an over-expanded nozzle.

Assumptions and limits

  • Ideal nozzle, frozen flow, perfect gas, axial exit.

References

  • Ideal rocket nozzle relations

Questions and answers

Why does a vacuum nozzle have a bigger area ratio?

Expanding further lowers the exit pressure and raises the exhaust velocity; at sea level the large exit would over-expand and lose thrust (and may separate), but in vacuum there is no penalty.

What is the characteristic velocity?

c* = p_c A_t/ṁ measures combustion performance alone, independent of the nozzle; about 1,500–1,800 m/s for kerosene–oxygen.

What do the defaults represent?

An illustrative kerosene–oxygen engine: 7 MPa and 3,400 K in the chamber, γ 1.22, exhaust molar mass 22.5, area ratio 16, 200 cm² throat, at sea level.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Sutton and Biblarz, Rocket Propulsion Elements, 8th ed. (Wiley, 2010), ch. 3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.