Worked example
Example: Utility Ljungstrom heater 1.5 rpm, 10 m rotor, 1.8 m deep. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Rotor speed | 1.5000 rpm |
| Gas-side sector angle | 180.00 ° |
| Air-side sector angle | 140.00 ° |
| Rotor diameter | 10.000 m |
| Shaft (hub) diameter | 1.2000 m |
| Matrix height (depth) | 1.8000 m |
| Matrix material density | 7,850.0 kg/m³ |
| Matrix specific heat | 0.48000 kJ/(kg·K) |
| Packing density (area per matrix volume) | 0.35000 m²/L |
| Matrix porosity | 80.000 % |
| Share of the rotor face covered by seals | 8.0000 % |
| Gas-side heat transfer coefficient | 45.000 W/(m²·K) |
| Air-side heat transfer coefficient | 40.000 W/(m²·K) |
| Flue gas flow | 576,000 kg/h |
| Flue gas specific heat | 1.1000 kJ/(kg·K) |
| Air flow | 540,000 kg/h |
| Air specific heat | 1.0100 kJ/(kg·K) |
| Gas inlet temperature | 360.00 °C |
| Air inlet temperature | 30.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Capacity rate ratio C_min/C_max | 0.86080 |
| Conductance ratio (C_min side / C_max side) | 0.69136 |
| Matrix mass | 218,757 kg |
| Matrix capacity ratio C_r/C_min | 17.327 |
| Total matrix surface | 44,866 m² |
| Modified number of transfer units | 3.0641 |
| Counterflow recuperator effectiveness | 79.259 % |
| Regenerator effectiveness (Kays–London) | 79.223 % |
| Regenerator effectiveness (Razelos) | 79.218 % |
| Heat recovered | 39,608 kW |
| Gas outlet temperature | 134.96 °C |
| Air outlet temperature | 291.44 °C |
Open this example in the calculator and change any input.
Formula
\(C_r = M_wc_wN, \quad NTU_o = \frac{1}{C_{min}}\left[\frac{1}{(hA)_h} + \frac{1}{(hA)_c}\right]^{-1}, \quad \varepsilon_{cf} = \frac{1 - e^{-NTU_o(1 - C^*)}}{1 - C^*e^{-NTU_o(1 - C^*)}}\)
\(\varepsilon = \varepsilon_{cf}\left[1 - \frac{1}{9C_r^{*1.93}}\right], \quad q = \varepsilon C_{min}(T_{h,i} - T_{c,i})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N\) | Rotor speed | rad/s |
| \(\theta_h\) | Gas-side sector angle | rad |
| \(\theta_c\) | Air-side sector angle | rad |
| \(D\) | Rotor diameter | m |
| \(d_s\) | Shaft (hub) diameter | m |
| \(H\) | Matrix height (depth) | m |
| \(\rho_w\) | Matrix material density | kg/m³ |
| \(c_w\) | Matrix specific heat | J/(kg·K) |
| \(\beta\) | Packing density (area per matrix volume) | m²/m³ |
| \(\sigma\) | Matrix porosity | - |
| \(f_s\) | Share of the rotor face covered by seals | - |
| \(h_h\) | Gas-side heat transfer coefficient | W/(m²·K) |
| \(h_c\) | Air-side heat transfer coefficient | W/(m²·K) |
| \(\dot m_h\) | Flue gas flow | kg/s |
| \(c_{p,h}\) | Flue gas specific heat | J/(kg·K) |
| \(\dot m_c\) | Air flow | kg/s |
| \(c_{p,c}\) | Air specific heat | J/(kg·K) |
| \(T_{h,i}\) | Gas inlet temperature | K |
| \(T_{c,i}\) | Air inlet temperature | K |
| \(C^*\) | Capacity rate ratio C_min/C_max | - |
| \((hA)^*\) | Conductance ratio (C_min side / C_max side) | - |
| \(M_w\) | Matrix mass | kg |
| \(C_r^*\) | Matrix capacity ratio C_r/C_min | - |
| \(A\) | Total matrix surface | m² |
| \(NTU_o\) | Modified number of transfer units | - |
| \(\varepsilon_{cf}\) | Counterflow recuperator effectiveness | - |
| \(\varepsilon\) | Regenerator effectiveness (Kays–London) | - |
| \(\varepsilon_R\) | Regenerator effectiveness (Razelos) | - |
| \(q\) | Heat recovered | W |
| \(T_{h,o}\) | Gas outlet temperature | K |
| \(T_{c,o}\) | Air outlet temperature | K |
Method and standards
ε-NTU_o method for rotary regenerators.
Where it is used
- Boiler and gas turbine rotary air heaters.
- HVAC energy recovery wheels.
Common mistakes
- Using the full rotor face as heat transfer area (seals and hub carry none).
- Ignoring the rotor speed effect at low rpm.
Assumptions and limits
- Balanced, counterflow regenerator; no leakage or longitudinal conduction.
Questions and answers
Why does rotor speed matter?
The matrix must store the heat it carries between the gas and air sides; above C_r* ≈ 5 the effectiveness approaches the counterflow recuperator, below it falls steeply.
What is the effect of the seals?
Radial seals cover part of the face and carry no flow, so they reduce the effective surface; leakage across them is a separate loss checked with the air heater leakage calculator.
What do the defaults represent?
An illustrative case: Utility Ljungstrom heater 1.5 rpm, 10 m rotor, 1.8 m deep. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Shah and Sekulić, Fundamentals of Heat Exchanger Design (Wiley, 2003), secs. 5.2 and 5.3, eqs. 5.48 and 5.62 to 5.67 (Kays and London; Razelos, 1980) and Example 5.1