Rotary Regenerative Air Heater (Ljungström) Effectiveness

Matrix capacity rate, NTU and effectiveness of a rotary regenerator such as a boiler Ljungström air heater (Kays–London, Razelos), with duty and outlet temperatures.

Thermal power plantProcess steam and utilities

Inputs

Examples: Utility Ljungstrom heater 1.5 rpm, 10 m rotor, 1.8 m deepSlow rotor 0.5 rpm (low Cr*)

Accepted: 0.095493 to 954.93 rpm
Accepted: 10 to 340 °
Accepted: 10 to 340 °
Accepted: 0.2 to 25 m
Accepted: 0 to 5 m
Accepted: 0.05 to 5 m
Accepted: 500 to 10,000 kg/m³
Accepted: 0.1 to 2 kJ/(kg·K)
Accepted: 0.05 to 10 m²/L
Accepted: 30 to 98 %
Accepted: 0 to 50 %
Accepted: 1 to 1,000 W/(m²·K)
Accepted: 1 to 1,000 W/(m²·K)
Accepted: 36 to 7,200,000 kg/h
Accepted: 0.8 to 1.5 kJ/(kg·K)
Accepted: 36 to 7,200,000 kg/h
Accepted: 0.8 to 1.5 kJ/(kg·K)
Accepted: 26.85 to 726.85 °C
Accepted: -43.15 to 126.85 °C

Results

Valid for (hA)* between 0.25 and 4 and ε up to about 0.9 (Lambertson; Kays and London). Leakage past the seals, which in boiler air heaters is often 5–15 % of the air, is not included.

Capacity rate ratio C_min/C_max0.86080
Conductance ratio (C_min side / C_max side)0.69136
Matrix mass218,757kg
Matrix capacity ratio C_r/C_min17.327
Total matrix surface44,866m²
Modified number of transfer units3.0641
Counterflow recuperator effectiveness79.259%
Regenerator effectiveness (Kays–London)79.223%
Regenerator effectiveness (Razelos)79.218%
Heat recovered39,608kW
Gas outlet temperature134.96°C
Air outlet temperature291.44°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Utility Ljungstrom heater 1.5 rpm, 10 m rotor, 1.8 m deep. The inputs, in the units selected above:

InputValue
Rotor speed1.5000 rpm
Gas-side sector angle180.00 °
Air-side sector angle140.00 °
Rotor diameter10.000 m
Shaft (hub) diameter1.2000 m
Matrix height (depth)1.8000 m
Matrix material density7,850.0 kg/m³
Matrix specific heat0.48000 kJ/(kg·K)
Packing density (area per matrix volume)0.35000 m²/L
Matrix porosity80.000 %
Share of the rotor face covered by seals8.0000 %
Gas-side heat transfer coefficient45.000 W/(m²·K)
Air-side heat transfer coefficient40.000 W/(m²·K)
Flue gas flow576,000 kg/h
Flue gas specific heat1.1000 kJ/(kg·K)
Air flow540,000 kg/h
Air specific heat1.0100 kJ/(kg·K)
Gas inlet temperature360.00 °C
Air inlet temperature30.000 °C

Applying the formula below gives:

ResultValue
Capacity rate ratio C_min/C_max0.86080
Conductance ratio (C_min side / C_max side)0.69136
Matrix mass218,757 kg
Matrix capacity ratio C_r/C_min17.327
Total matrix surface44,866 m²
Modified number of transfer units3.0641
Counterflow recuperator effectiveness79.259 %
Regenerator effectiveness (Kays–London)79.223 %
Regenerator effectiveness (Razelos)79.218 %
Heat recovered39,608 kW
Gas outlet temperature134.96 °C
Air outlet temperature291.44 °C

Open this example in the calculator and change any input.

Formula

\(C_r = M_wc_wN, \quad NTU_o = \frac{1}{C_{min}}\left[\frac{1}{(hA)_h} + \frac{1}{(hA)_c}\right]^{-1}, \quad \varepsilon_{cf} = \frac{1 - e^{-NTU_o(1 - C^*)}}{1 - C^*e^{-NTU_o(1 - C^*)}}\)

\(\varepsilon = \varepsilon_{cf}\left[1 - \frac{1}{9C_r^{*1.93}}\right], \quad q = \varepsilon C_{min}(T_{h,i} - T_{c,i})\)

Variables

Symbol Meaning SI unit
\(N\) Rotor speed rad/s
\(\theta_h\) Gas-side sector angle rad
\(\theta_c\) Air-side sector angle rad
\(D\) Rotor diameter m
\(d_s\) Shaft (hub) diameter m
\(H\) Matrix height (depth) m
\(\rho_w\) Matrix material density kg/m³
\(c_w\) Matrix specific heat J/(kg·K)
\(\beta\) Packing density (area per matrix volume) m²/m³
\(\sigma\) Matrix porosity -
\(f_s\) Share of the rotor face covered by seals -
\(h_h\) Gas-side heat transfer coefficient W/(m²·K)
\(h_c\) Air-side heat transfer coefficient W/(m²·K)
\(\dot m_h\) Flue gas flow kg/s
\(c_{p,h}\) Flue gas specific heat J/(kg·K)
\(\dot m_c\) Air flow kg/s
\(c_{p,c}\) Air specific heat J/(kg·K)
\(T_{h,i}\) Gas inlet temperature K
\(T_{c,i}\) Air inlet temperature K
\(C^*\) Capacity rate ratio C_min/C_max -
\((hA)^*\) Conductance ratio (C_min side / C_max side) -
\(M_w\) Matrix mass kg
\(C_r^*\) Matrix capacity ratio C_r/C_min -
\(A\) Total matrix surface m²
\(NTU_o\) Modified number of transfer units -
\(\varepsilon_{cf}\) Counterflow recuperator effectiveness -
\(\varepsilon\) Regenerator effectiveness (Kays–London) -
\(\varepsilon_R\) Regenerator effectiveness (Razelos) -
\(q\) Heat recovered W
\(T_{h,o}\) Gas outlet temperature K
\(T_{c,o}\) Air outlet temperature K

Method and standards

ε-NTU_o method for rotary regenerators.

Where it is used

  • Boiler and gas turbine rotary air heaters.
  • HVAC energy recovery wheels.

Common mistakes

  • Using the full rotor face as heat transfer area (seals and hub carry none).
  • Ignoring the rotor speed effect at low rpm.

Assumptions and limits

  • Balanced, counterflow regenerator; no leakage or longitudinal conduction.

Questions and answers

Why does rotor speed matter?

The matrix must store the heat it carries between the gas and air sides; above C_r* ≈ 5 the effectiveness approaches the counterflow recuperator, below it falls steeply.

What is the effect of the seals?

Radial seals cover part of the face and carry no flow, so they reduce the effective surface; leakage across them is a separate loss checked with the air heater leakage calculator.

What do the defaults represent?

An illustrative case: Utility Ljungstrom heater 1.5 rpm, 10 m rotor, 1.8 m deep. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Shah and Sekulić, Fundamentals of Heat Exchanger Design (Wiley, 2003), secs. 5.2 and 5.3, eqs. 5.48 and 5.62 to 5.67 (Kays and London; Razelos, 1980) and Example 5.1

Related calculators