Inputs

Examples: 40 kWh, 20 → 80 % on 7.4 kW at 8 per kWhBus 300 kWh, 10 → 90 % on 120 kW

Results

Constant charger power. Fast chargers taper above about 80 % state of charge, so the last 20 % takes much longer than this estimate.

Energy into the battery24.000kWh
Energy from the grid26.667kWh
Charging time3.6036h
Charging cost213.33

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 kWh, 20 → 80 % on 7.4 kW at 8 per kWh. The inputs, in the units selected above:

InputValue
Battery capacity40.000 kWh
Starting state of charge20.000 %
Final state of charge80.000 %
Charger power (drawn from the grid)7.4000 kW
Charging efficiency90.000 %
Tariff per kWh (your currency)8.0000 -

Applying the formula below gives:

ResultValue
Energy into the battery24.000 kWh
Energy from the grid26.667 kWh
Charging time3.6036 h
Charging cost213.33

Open this example in the calculator and change any input.

Formula

\(E_{grid} = \frac{E_b(SOC_2 - SOC_1)}{\eta_c}, \quad t = \frac{E_{grid}}{P_c}, \quad C = \frac{E_{grid}}{3.6\times10^6\ \mathrm{J/kWh}}\,c\)

Variables

Symbol Meaning SI unit
\(E_b\) Battery capacity J
\(SOC_1\) Starting state of charge -
\(SOC_2\) Final state of charge -
\(P_c\) Charger power (drawn from the grid) W
\(\eta_c\) Charging efficiency -
\(c\) Tariff per kWh (your currency) -
\(E_{bat}\) Energy into the battery J
\(E_{grid}\) Energy from the grid J
\(t\) Charging time s
\(C\) Charging cost -

Method and standards

Energy balance.

Where it is used

  • Workplace charger planning.
  • Fleet running cost.

Common mistakes

  • Using the full battery capacity.
  • Ignoring the taper above 80 %.

Assumptions and limits

  • Constant power (no taper above about 80 %).
  • P_c is the power drawn from the grid (AC input), so the losses are inside it; if the charger is rated by its DC output, divide by the efficiency first.
  • Tariff in your currency per kWh.

References

  • Energy balance of charging (definitions)

Questions and answers

Why is grid energy more than battery energy?

Charger, cable and battery losses take 5–15 %.

Why charge to 80 %?

Charging slows above 80 % and battery life is better if it is not kept full.

What do the defaults represent?

A 40 kWh car charged from 20 % to 80 % on a 7.4 kW wall charger.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.