Desuperheater Spray Water Flow

Spray water needed to cool superheated steam to a target temperature in a desuperheater, attemperator or PRDS, from an energy balance with IAPWS-IF97 enthalpies.

Inputs

Examples: PRDS 64 bar(a) / 480 °C to 12 bar(a) / 250 °CAttemperator 100 bar(a), 560 °C to 540 °CLP header 6 bar(a), 300 °C to 180 °C

Inlet steam

Outlet steam

Equal to the inlet pressure for an attemperator; lower for a pressure-reducing and desuperheating station (PRDS).

Spray water

Results

Spray water flow541.23kg/h
Outlet steam flow5,541.2kg/h
Spray water per kg of inlet steam10.825%
Saturation temperature at the outlet158.83°C
Outlet superheat21.168K
Inlet steam enthalpy3,062.1kJ/kg
Outlet steam enthalpy2,806.0kJ/kg
Spray water enthalpy440.86kJ/kg

Download PDF Link to this result

Log in to save calculations to your dashboard.

Formula

Mass and energy balance across the desuperheater (throttling, if any, is adiabatic):

\(\dot m_1 h_1 + \dot m_w h_w = \dot m_2 h_2 \qquad \dot m_2 = \dot m_1 + \dot m_w\)

\(\dot m_w = \dot m_1\,\frac{h_1 - h_2}{h_2 - h_w} \qquad \Delta T_{sh,2} = T_2 - T_{sat,2}\)

Variables

Symbol Meaning SI unit
\(\dot m_1\) inlet steam flow kg/s
\(p_1\) inlet steam absolute pressure Pa
\(T_1\) inlet steam temperature K
\(p_2\) outlet steam absolute pressure Pa
\(T_2\) outlet steam temperature (target) K
\(p_w\) spray water absolute pressure Pa
\(T_w\) spray water temperature K
\(\dot m_w\) spray water flow kg/s
\(\dot m_2\) outlet steam flow kg/s
\(\dot m_w / \dot m_1\) spray water per kg of inlet steam –
\(T_{sat,2}\) saturation temperature at the outlet pressure K
\(\Delta T_{sh,2}\) outlet superheat K
\(h_1\) inlet steam enthalpy J/kg
\(h_2\) outlet steam enthalpy J/kg
\(h_w\) spray water enthalpy J/kg

Method and standards

Enthalpies from FireCAD's IAPWS-IF97 implementation (region 2 for the steam, region 1 for the water). The balance is the standard first-law statement for an adiabatic mixing device with no shaft work.

Assumptions and limits

  • No heat loss from the desuperheater and piping.
  • All spray water evaporates; the outlet is superheated steam.
  • Inlet and outlet steam must be superheated; spray water must be liquid.

References

  • IAPWS R7-97(2012) IF97

Questions and answers

How much spray water does a PRDS need?

For 20 t/h of steam at 64 bar(a) and 480 °C reduced to 12 bar(a) and 250 °C with spray water at 130 °C, about 1.01 kg/s (3.6 t/h), or 18 % of the inlet steam. The outlet flow is the inlet steam plus the spray.

Can I desuperheat to saturation?

Not with this balance. Spray desuperheaters need some superheat at the outlet (commonly at least a few kelvin) to evaporate every droplet; the calculator requires a target above the saturation temperature.

Does the spray water pressure matter?

Only through the water enthalpy, which changes little with pressure. It must be above the steam pressure for the water to enter the nozzles.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.