Equivalent Evaporation (From and At 100 °C)

Boiler output expressed as water evaporated from and at 100 °C: factor of evaporation, equivalent evaporation and evaporation ratio per kg of fuel.

Inputs

Examples: Shell boiler 10 t/h, 10.5 bar(a) saturated, feed 105 °C, coal 1.6 t/hWater-tube 50 t/h, 66 bar(a) / 485 °C, feed 150 °C, coal 7.5 t/hPackage boiler 2 t/h, 8 bar(a) saturated, feed 30 °C

At the boiler outlet. Absolute; choose a gauge unit to enter gauge readings.
Enter 0 to skip the evaporation ratios.

Results

Equivalent evaporation from and at 100 °C2,341.6kg/h
Factor of evaporation1.1708
Steam enthalpy2,768.3kJ/kg
Feedwater enthalpy126.47kJ/kg
Latent heat at 100 °C2,256.5kJ/kg

Download PDF Link to this result

Log in to save calculations to your dashboard.

Formula

\(F = \frac{h_s - h_{fw}}{h_{fg,100}} \qquad \dot m_e = F\,\dot m_s\)

\(\text{actual evaporation ratio} = \frac{\dot m_s}{\dot m_f} \qquad \text{equivalent evaporation ratio} = \frac{\dot m_e}{\dot m_f}\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) steam generated kg/s
\(p\) steam absolute pressure at the boiler outlet Pa
\(\text{state}\) dry saturated, or superheated at \(T_s\) –
\(T_s\) steam temperature when superheated K
\(T_{fw}\) feedwater temperature K
\(\dot m_f\) fuel burnt (optional) kg/s
\(\dot m_e\) equivalent evaporation from and at 100 °C kg/s
\(F\) factor of evaporation –
\(\dot m_s / \dot m_f\) actual evaporation ratio kg/kg
\(\dot m_e / \dot m_f\) equivalent evaporation ratio kg/kg
\(h_s\) steam enthalpy J/kg
\(h_{fw}\) feedwater enthalpy J/kg
\(h_{fg,100}\) latent heat of vaporisation at 100 °C J/kg

Method and standards

The "from and at 100 °C" rating convention used for shell boilers (BS 845-1 and boiler-maker practice). All enthalpies come from FireCAD's IAPWS-IF97 implementation; \(h_{fg,100}\) is evaluated on the saturation line at 373.15 K.

Assumptions and limits

  • Feedwater enthalpy is taken at the steam pressure (the difference to the feed pump outlet pressure is negligible here).
  • Wet steam and blowdown are not included; for boiler efficiency use the PTC 4 calculators.

References

  • IAPWS R7-97(2012) IF97
  • BS 845-1

Questions and answers

What does "from and at 100 °C" mean?

It is the mass of water at 100 °C that the same heat would turn into dry saturated steam at 100 °C. It lets boilers with different steam conditions and feedwater temperatures be compared on one basis.

Why is the factor of evaporation above 1?

Raising feedwater at 105 °C to dry saturated steam at 10.5 bar(a) needs 2 338 kJ/kg, more than the 2 256 kJ/kg latent heat at 100 °C, so the factor is 1.036.

Which latent heat at 100 °C is used?

2 256.47 kJ/kg from IAPWS-IF97 at 100 °C. Older references round it to 2 257 kJ/kg (539 kcal/kg); the difference is 0.02 %.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.